Datasheet
SDAS153E − DECEMBER 1982 − REVISED AUGUST 1995
4
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
POST OFFICE BOX 1443
• HOUSTON, TEXAS 77251−1443
switching characteristics (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
V
CC
= 4.5 V to 5.5 V,
C
L
= 50 pF,
R1 = 500 Ω
,
R2 = 500 Ω,
T
A
= MIN to MAX
†
UNIT
(INPUT)
(OUTPUT)
SN54ALS241C SN74ALS241C
MIN MAX MIN MAX
t
PLH
A
Y
3 31 2 11
ns
t
PHL
A
Y
1 17 3 10
ns
t
PZH
1OE
Y
3 33 3 21
ns
t
PZL
1OE Y
3 27 4 21
ns
t
PHZ
1OE
Y
2 17 1 10
ns
t
PLZ
1OE Y
2 32 2 15
ns
t
PZH
2OE
Y
3 38 4 21
ns
t
PZL
2OE Y
3 30 5 21
ns
t
PHZ
2OE
Y
2 17 2 10
ns
t
PLZ
2OE
Y
3 35 3 15
ns
†
For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
‡
Supply voltage, V
CC
7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input voltage, V
I
7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Voltage applied to a disabled 3-state output 5.5 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating free-air temperature range, T
A
: SN54AS241A −55°C to 125°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SN74AS241A 0°C to 70°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range −65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
‡
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
recommended operating conditions
SN54AS241A SN74AS241A
UNIT
MIN NOM MAX MIN NOM MAX
UNIT
V
CC
Supply voltage 4.5 5 5.5 4.5 5 5.5 V
V
IH
High-level input voltage 2 2 V
V
IL
Low-level input voltage 0.8 0.8 V
I
OH
High-level output current −12 −15 mA
I
OL
Low-level output current 48 64 mA
T