Datasheet
SDAS125B − MARCH 1984 − REVISED DECEMBER 1994
2−6
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
POST OFFICE BOX 1443
• HOUSTON, TEXAS 77251−1443
switching characteristics (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
V
CC
= 4.5 V to 5.5 V,
C
L
= 50 pF,
R
L
= 500 Ω
,
T
A
= MIN to MAX
†
UNIT
PARAMETER
(INPUT)
(OUTPUT)
SN54ALS169B SN74ALS169B
UNIT
MIN MAX MIN MAX
f
max
22 40 MHz
t
PLH
CLK
RCO
3 20 3 20
ns
t
PHL
CLK
RCO
6 25 6 20
ns
t
PLH
CLK
Any Q
2 20 2 15
ns
t
PHL
CLK Any Q
5 23 5 20
ns
t
PLH
ENT
RCO
2 16 2 13
ns
t
PHL
ENT RCO
3 24 3 16
ns
t
PLH
U/D
RCO
4 22 5 19
ns
t
PHL
U/D
RCO
5 26 5 19
ns
†
For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
‡
Supply voltage, V
CC
7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input voltage, V
I
7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating free-air temperature range, T
A
: SN54AS169A −55°C to 125°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SN74AS169A 0°C to 70°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range −65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
‡
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
recommended operating conditions
SN54AS169A SN74AS169A
UNIT
MIN NOM MAX MIN NOM MAX
UNIT
V
CC
Supply voltage 4.5 5 5.5 4.5 5 5.5 V
V
IH
High-level input voltage 2 2 V
V
IL
Low-level input voltage 0.8 0.8 V
I
OH
High-level output current −2 −2 mA
I
OL
Low-level output current 20 20 mA
f
clock
* Clock frequency 0 60 0 75 MHz
t
w
* Pulse duration, CLK high or low 7.7 6.7 ns
A, B, C, or D 10 8
t
su
*
Setup time before CLK↑
ENP or ENT 10 8
ns
t
su
* Setup time before CLK↑
LOAD
10 8
ns
U/D 14 11
t
h
* Hold time, data after CLK↑ 2 0 ns
T
A
Operating free-air temperature −55 125 0 70 °C
* On products compliant to MIL-STD-883, Class B, this parameter is based on characterization data but is not production tested.