Datasheet

SN54ALS138A, SN54AS138, SN74ALS138A, SN74AS138
3-LINE TO 8-LINE DECODERS/DEMULTIPLEXERS
SDAS055E – APRIL 1982 – REVISED JULY 1996
4
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, V
CC
7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input voltage, V
I
7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating free-air temperature range, T
A
: SN54ALS138A 55°C to 125°C. . . . . . . . . . . . . . . . . . . . . . . . . . .
SN74ALS138A 0°C to 70°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range, T
stg
–65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
recommended operating conditions
SN54ALS138A SN74ALS138A
UNIT
MIN NOM MAX MIN NOM MAX
UNIT
V
CC
Supply voltage 4.5 5 5.5 4.5 5 5.5 V
V
IH
High-level input voltage 2 2 V
V
IL
Low-level input voltage 0.7 0.8 V
I
OH
High-level output current 0.4 0.4 mA
I
OL
Low-level output current 4 8 mA
T
A
Operating free-air temperature –55 125 0 70 °C
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
SN54ALS138A SN74ALS138A
UNIT
PARAMETER
TEST
CONDITIONS
MIN TYP
MAX MIN TYP
MAX
UNIT
V
IK
V
CC
= 4.5 V, I
I
= –18 mA 1.5 1.5 V
V
OH
V
CC
= 4.5 V, I
OH
= –0.4 mA V
CC
–2 V
CC
–2 V
V
OL
V
CC
=45V
I
OL
= 4 mA 0.25 0.4 0.25 0.4
V
V
OL
V
CC
=
4
.
5
V
I
OL
= 8 mA 0.35 0.5
V
I
I
V
CC
= 5.5 V, V
I
= 7 V 0.1 0.1 mA
I
IH
V
CC
= 5.5 V, V
I
= 2.7 V 20 20 µA
I
IL
V
CC
= 5.5 V, V
I
= 0.4 V 0.1 0.1 mA
I
O
§
V
CC
= 5.5 V, V
O
= 2.25 V –20 –112 –30 –112 mA
I
CC
V
CC
= 5.5 V 5 10 5 10 mA
All typical values are at V
CC
= 5 V, T
A
= 25°C.
§
The output conditions have been chosen to produce a current that closely approximates one half of the true short-circuit output current, I
OS
.
switching characteristics (see Figure 1)
PARAMETER
FROM
(
INPUT
)
TO
(
OUTPUT
)
V
CC
= 4.5 V to 5.5 V,
C
L
= 50 pF,
R
L
= 500
,
T
A
= MIN to MAX
UNIT
(INPUT)
(OUTPUT)
SN54ALS138A SN74ALS138A
MIN MAX MIN MAX
t
PLH
ABC
Any Y
2 28 5 22
ns
t
PHL
A
,
B
,
C
An
y
Y
6 22 6 18
ns
t
PLH
GorG
Any Y
2 22 3 17
ns
t
PHL
G
or
G
An
y
Y
4 21 4 17
ns
For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.