Datasheet

SN54ALS1035, SN74ALS1035
HEX NONINVERTING BUFFERS
WITH OPEN-COLLECTOR OUTPUTS
SDAS243B APRIL 1982 REVISED AUGUST 2001
3
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
SN54ALS1035 SN74ALS1035
UNIT
PARAMETER
TEST
CONDITIONS
MIN TYP
MAX MIN TYP
MAX
UNIT
V
IK
V
CC
= 4.5 V, I
I
= 18 mA 1.5 1.5 V
V
OL
V
CC
=45V
I
OL
= 12 mA 0.25 0.4 0.25 0.4
V
V
OL
V
CC
=
4
.
5
V
I
OL
= 24 mA 0.35 0.5
V
I
OH
V
CC
= 4.5 V, V
OH
= 5.5 V 0.1 0.1 mA
I
I
V
CC
= 5.5 V, V
I
= 7 V 0.1 0.1 mA
I
IH
V
CC
= 5.5 V, V
I
= 2.7 V 20 20 µA
I
IL
V
CC
= 5.5 V, V
I
= 0.4 V 0.1 0.1 mA
I
CCH
V
CC
= 5.5 V, V
I
= 4.5 V 3 6 3 6 mA
I
CCL
V
CC
= 5.5 V, V
I
= 0 8 14 8 14 mA
All typical values are at V
CC
= 5 V, T
A
= 25°C.
switching characteristics (see Figure 1)
PARAMETER
FROM
(
INPUT
)
TO
OUTPUT
V
CC
= 4.5 V to 5.5 V,
C
L
= 50 pF,
R
L
= 680 ,
T
A
= MIN to MAX
UNIT
(INPUT)
SN54ALS1035 SN74ALS1035
MIN MAX MIN MAX
t
PLH
A
5 35 5 30
ns
t
PHL
A
2 14 2 12
ns
For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.