Datasheet


   
SCLS320N − MARCH 1996 − REVISED JUNE 2005
3
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
switching characteristics over recommended operating free-air temperature range,
V
CC
= 5 V ± 0.5 V (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
TO
LOAD
T
A
= 25°C
UNIT
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
LOAD
CAPACITANCE
MIN TYP MAX
UNIT
t
PLH
A or B
Y
C
L
= 15 pF
5 6.9 1 8
ns
t
PHL
A or B Y C
L
= 15 pF
5 6.9 1 8
ns
t
PLH
A or B
Y
C
L
= 50 pF
5.5 7.9 1 9
ns
t
PHL
A or B
Y
C
L
= 50 pF
5.5 7.9 1 9
ns
operating characteristics, V
CC
= 5 V, T
A
= 25°C
PARAMETER TEST CONDITIONS TYP UNIT
C
pd
Power dissipation capacitance No load, f = 1 MHz 11.5 pF