Datasheet

SN54AHCT174, SN74AHCT174
HEX D-TYPE FLIP-FLOPS
WITH CLEAR
SCLS419F JUNE 1998 REVISED APRIL 2002
4
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
switching characteristics over recommended operating free-air temperature range,
V
CC
= 5 V ± 0.5 V (unless otherwise noted) (see Figure 1)
PARAMETER
FROM TO LOAD
T
A
= 25°C SN54AHCT174 SN74AHCT174
UNIT
PARAMETER
(INPUT) (OUTPUT) CAPACITANCE
MIN TYP MAX MIN MAX MIN MAX
UNIT
f
C
L
= 15 pF 100** 135** 80** 80
MHz
f
max
C
L
= 50 pF 80 115 65 65
MHz
t
PHL
CLR Any Q C
L
= 15 pF 7.6** 10.4** 1** 13** 1 13 ns
t
PLH
CLK
Any Q
C
L
=15
p
F
5.8** 7.8** 1** 9** 1 9
ns
t
PHL
CLK
Any
Q
C
L
=
15
pF
5.8** 7.8** 1** 9** 1 9
ns
t
PHL
CLR Any Q C
L
= 50 pF 8.1 11.4 1 13 1 13 ns
t
PLH
CLK
Any Q
C
L
=50
p
F
6.3 8.8 1 10 1 10
ns
t
PHL
CLK
Any
Q
C
L
=
50
pF
6.3 8.8 1 10 1 10
ns
t
sk(o)
C
L
= 50 pF 1*** 1 ns
** On products compliant to MIL-PRF-38535, this parameter is not production tested.
*** On products compliant to MIL-PRF-38535, this parameter does not apply.
noise characteristics V
CC
= 5 V, C
L
= 50 pF, T
A
= 25°C (see Note 4)
PARAMETER
SN74AHCT174
UNIT
PARAMETER
MIN TYP MAX
UNIT
V
OL(P)
Quiet output, maximum dynamic V
OL
0.8 V
V
OL(V)
Quiet output, minimum dynamic V
OL
0.8 V
V
OH(V)
Quiet output, minimum dynamic V
OH
4 V
V
IH(D)
High-level dynamic input voltage 2 V
V
IL(D)
Low-level dynamic input voltage 0.8 V
NOTE 4: Characteristics are for surface-mount packages only.
operating characteristics, T
A
= 25°C
PARAMETER TEST CONDITIONS TYP UNIT
C
pd
Power dissipation capacitance No load, f = 1 MHz 28 pF
PRODUCT PREVIEW information concerns products in the formative or
design phase of development. Characteristic data and other
specifications are design goals. Texas Instruments reserves the right to
change or discontinue these products without notice.