Datasheet

SN54AHC595, SN74AHC595
SCLS373J MAY 1996REVISED JULY 2013
www.ti.com
ELECTRICAL CHARACTERISTICS
over operating free-air temperature range (unless otherwise noted)
–40°C TO 125°C
–55°C TO 125°C –40°C TO 85°C
T
A
= 25°C Recommended
SN54AHC595
(1)
SN74AHC595
PARAMETER TEST CONDITIONS V
CC
UNIT
SN74AHC595
MIN TYP MAX MIN MAX MIN MAX MIN MAX
2 V 1.9 2 1.9 1.9 1.9
I
OH
= –50 µA 3 V 2.9 3 2.9 2.9 2.9
V
OH
4.5 V 4.4 4.5 4.4 4.4 4.4 V
I
OH
= –4 mA 3 V 2.58 2.48 2.48 2.48
I
OH
= –8 mA 4.5 V 3.94 3.8 3.8 3.8
2 V 0.1 0.1 0.1 0.1
I
OL
= 50 µA 3 V 0.1 0.1 0.1 0.1
V
OL
4.5 V 0.1 0.1 0.1 0.1 V
I
OH
= 4 mA 3 V 0.36 0.5 0.44 0.44
I
OH
= 8 mA 4.5 V 0.36 0.5 0.44 0.44
0 V to 5.5
I
I
V
I
= 5.5 V or GND ±0.1 ±1
(2)
±1 ±1 µA
V
V
I
= V
CC
or
GND,
V
O
= V
CC
or Q
A
I
OZ
5.5 V ±0.25 ±2.5 ±2.5 ±2.5
GND, Q
H
OE = V
IH
or
V
IL
,
V
I
= V
CC
or
I
CC
I
O
= 0 5.5 V 4 40 40 40 µA
GND,
C
i
V
I
= V
CC
or GND 5 V 3 10 10 pF
C
O
V
O
= V
CC
or GND, 5 V 5.5
(1) Product Preview.
(2) On products compliant to MIL-PRF-38535, this parameter is not production tested at VCC = 0 V.
TIMING REQUIREMENTS
over recommended operating free-air temperature range, VCC = 3.3 V ± 0.3 V (unless otherwise noted) (see Figure 1)
–40°C TO 125°C
–55°C TO 125°C –40°C TO 85°C
T
A
= 25°C Recommended
SN54AHC595
(1)
SN74AHC595
UNIT
SN74AHC595
MIN MAX MIN MAX MIN MAX MIN MAX
SRCLK high or low 5 5 5 6
t
W
Pulse duration RCLK high or low 5 5 5 6 ns
SRCLR low 5 5 5 6.5
SER before SRCLK 3.5 3.5 3.5 4.5
SRCLK before RCLK
(2)
8 8.5 8.5 9.5
t
su
Setup time ns
SRCLR low before RCLK 8 9 9 10
SRCLR high (inactive) before 3 3 3 4
SRCLK
t
h
Hold time SER after SRCLK 1.5 1.5 1.5 2.5 ns
(1) Product Preview.
(2) This setup time allows the storage register to receive stable data from the shift register. The clocks can be tied together, in which case
the shift register is one clock pulse ahead of the storage register.
6 Submit Documentation Feedback Copyright © 1996–2013, Texas Instruments Incorporated