Datasheet

SCLS603A − DECEMBER 2004 − REVISED APRIL 2008
4
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
switching characteristics over recommended operating free-air temperature range,
V
CC
= 5 V ± 0.5 V (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
LOAD
CAPACITANCE
T
A
= 25°C
T
A
= −40°C
TO 125°C
T
A
= −40°C
TO 85°C
UNIT
PARAMETER
(INPUT)
(OUTPUT)
CAPACITANCE
MIN TYP MAX MIN MAX MIN MAX
UNIT
t
PLH
A
Y
C
L
= 15 pF
3.5 5 1 6 1 6
ns
t
PHL
A Y C
L
= 15 pF
3.5 5 1 6 1 6
ns
t
PZH
OE
Y
C
L
= 15 pF
4.7 7.2 1 8.5 1 8.5
ns
t
PZL
OE
Y C
L
= 15 pF
4.7 7.2 1 8.5 1 8.5
ns
t
PHZ
OE
Y
C
L
= 15 pF
5 7.5 1 8 1 8
ns
t
PLZ
OE
Y C
L
= 15 pF
5 7.5 1 8 1 8
ns
t
PLH
A
Y
C
L
= 50 pF
5 7 1 8 1 8
ns
t
PHL
A Y C
L
= 50 pF
5 7 1 8 1 8
ns
t
PZH
OE
Y
C
L
= 50 pF
6.2 9.2 1 10.5 1 10.5
ns
t
PZL
OE
Y C
L
= 50 pF
6.2 9.2 1 10.5 1 10.5
ns
t
PHZ
OE
Y
C
L
= 50 pF
6 8.8 1 10 1 10
ns
t
PLZ
OE
Y
C
L
= 50 pF
6 8.8 1 10 1 10
ns
t
sk(o)
C
L
= 50 pF 1 1 ns
noise characteristics, V
CC
= 5 V, C
L
= 50 pF, T
A
= 25°C (see Note 4)
PARAMETER MIN MAX UNIT
V
OL(P)
Quiet output, maximum dynamic V
OL
0.8 V
V
OL(V)
Quiet output, minimum dynamic V
OL
−0.8 V
V
OH(V)
Quiet output, minimum dynamic V
OH
4.7 V
V
IH(D)
High-level dynamic input voltage 3.5 V
V
IL(D)
Low-level dynamic input voltage 1.5 V
NOTE 4: Characteristics are for surface-mount packages only.
operating characteristics, V
CC
= 5 V, T
A
= 25°C
PARAMETER TEST CONDITIONS TYP UNIT
C
pd
Power dissipation capacitance No load, f = 1 MHz 12 pF