Datasheet


 
  
SCLS603A − DECEMBER 2004 − REVISED APRIL 2008
3
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
V
CC
T
A
= 25°C
T
A
= −40°C
TO 125°C
T
A
= −40°C
TO 85°C
PARAMETER
TEST CONDITIONS
V
CC
MIN TYP MAX MIN MAX MIN MAX
2 V 1.9 2 1.9 1.9
I
OH
= −50 mA
3 V 2.9 3 2.9 2.9
V
OH
I
OH
= −50 mA
4.5 V 4.4 4.5 4.4 4.4
V
OH
I
OH
= −4 mA
3 V 2.58 2.48 2.48
I
OH
= −8 mA
4.5 V 3.94 3.8 3.8
2 V 0.1 0.1 0.1
I
OL
= 50 mA
3 V 0.1 0.1 0.1
V
OL
I
OL
= 50 mA
4.5 V 0.1 0.1 0.1
V
OL
I
OL
= 4 mA
3 V 0.36 0.5 0.44
I
OL
= 8 mA
4.5 V 0.36 0.5 0.44
I
I
V
I
= 5.5 V or GND 0 V to 5.5 V ±0.1 ±1 ±1 mA
I
OZ
V
O
= V
CC
or GND,
V
I
(OE
) = V
IL
or V
IH
5.5 V ±0.25 ±2.5 ±2.5 mA
I
CC
V
I
= V
CC
or GND, I
O
= 0 5.5 V 4 40 40 mA
C
i
V
I
= V
CC
or GND 5 V 2 10 10 pF
C
o
V
O
= V
CC
or GND 5 V 4 pF
For input and ouput, I
OZ
includes the input leakage current.
switching characteristics over recommended operating free-air temperature range,
V
CC
= 3.3 V ± 0.3 V (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
LOAD
CAPACITANCE
T
A
= 25°C
T
A
= −40°C
TO 125°C
T
A
= −40°C
TO 85°C
PARAMETER
(INPUT)
(OUTPUT)
CAPACITANCE
MIN TYP MAX MIN MAX MIN MAX
t
PLH
A
Y
C
L
= 15 pF
5 7 1 8.5 1 8.5
t
PHL
A Y C
L
= 15 pF
5 7 1 8.5 1 8.5
ns
t
PZH
OE
Y
C
L
= 15 pF
6 10.5 1 11 1 11
t
PZL
OE
Y C
L
= 15 pF
6 10.5 1 11 1 11
ns
t
PHZ
OE
Y
C
L
= 15 pF
7 11 1 12 1 12
t
PLZ
OE
Y C
L
= 15 pF
7 11 1 12 1 12
ns
t
PLH
A
Y
C
L
= 50 pF
7.5 10.5 1 12 1 12
t
PHL
A Y C
L
= 50 pF
7.5 10.5 1 12 1 12
ns
t
PZH
OE
Y
C
L
= 50 pF
8 14 1 16 1 16
t
PZL
OE
Y C
L
= 50 pF
8 14 1 16 1 16
ns
t
PHZ
OE
Y
C
L
= 50 pF
9 15.4 1 17.5 1 17.5
t
PLZ
OE
Y C
L
= 50 pF
9 15.4 1 17.5 1 17.5
ns
t
sk(o)
C
L
= 50 pF 1.5 1.5 ns