Datasheet

SN54AHC244, SN74AHC244
OCTAL BUFFERS/DRIVERS
WITH 3-STATE OUTPUTS
SCLS226J − OCTOBER 1995 − REVISED JULY 2003
4
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
switching characteristics over recommended operating free-air temperature range,
V
CC
= 3.3 V ± 0.3 V (unless otherwise noted) (see Figure 1)
PARAMETER
FROM TO LOAD
T
A
= 25°C SN54AHC244 SN74AHC244
UNIT
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
LOAD
CAPACITANCE
MIN TYP MAX MIN MAX MIN MAX
UNIT
t
PLH
A
Y
C 15 pF
5.8* 8.4* 1* 10* 1 10
ns
t
PHL
A Y C
L
= 15 pF
5.8* 8.4* 1* 10* 1 10
ns
t
PZH
OE
Y
C 15 pF
6.6* 10.6* 1* 12.5* 1 12.5
ns
t
PZL
OE
Y C
L
= 15 pF
6.6* 10.6* 1* 12.5* 1 12.5
ns
t
PHZ
OE
Y
C 15 pF
5* 9.7* 1* 11* 1 11
ns
t
PLZ
OE
Y C
L
= 15 pF
5* 9.7* 1* 11* 1 11
ns
t
PLH
A
Y
C 50 pF
8.3 11.9 1 13.5 1 13.5
ns
t
PHL
A Y C
L
= 50 pF
8.3 11.9 1 13.5 1 13.5
ns
t
PZH
OE
Y
C 50 pF
9.1 14.1 1 16 1 16
ns
t
PZL
OE
Y C
L
= 50 pF
9.1 14.1 1 16 1 16
ns
t
PHZ
OE
Y
C 50 pF
10.3 14 1 16 1 16
ns
t
PLZ
OE
Y C
L
= 50 pF
10.3 14 1 16 1 16
ns
t
sk(o)
C
L
= 50 pF 1.5** 1.5 ns
On products compliant to MIL-PRF-38535, this parameter is not production tested.
∗∗
On products compliant to MIL-PRF-38535, this parameter does not apply.
switching characteristics over recommended operating free-air temperature range,
V
CC
= 5 V ± 0.5 V (unless otherwise noted) (see Figure 1)
PARAMETER
FROM TO LOAD
T
A
= 25°C SN54AHC244 SN74AHC244
UNIT
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
LOAD
CAPACITANCE
MIN TYP MAX MIN MAX MIN MAX
UNIT
t
PLH
A
Y
C 15 pF
3.9* 5.5* 1* 6.5* 1 6.5
ns
t
PHL
A Y C
L
= 15 pF
3.9* 5.5* 1* 6.5* 1 6.5
ns
t
PZH
OE
Y
C 15 pF
4.7* 7.3* 1* 8.5* 1 8.5
ns
t
PZL
OE
Y C
L
= 15 pF
4.7* 7.3* 1* 8.5* 1 8.5
ns
t
PHZ
OE
Y
C 15 pF
5* 7.2* 1* 8.5* 1 8.5
ns
t
PLZ
OE
Y C
L
= 15 pF
5* 7.2* 1* 8.5* 1 8.5
ns
t
PLH
A
Y
C 50 pF
5.4 7.5 1 8.5 1 8.5
ns
t
PHL
A Y C
L
= 50 pF
5.4 7.5 1 8.5 1 8.5
ns
t
PZH
OE
Y
C 50 pF
6.2 9.3 1 10.5 1 10.5
ns
t
PZL
OE
Y C
L
= 50 pF
6.2 9.3 1 10.5 1 10.5
ns
t
PHZ
OE
Y
C 50 pF
6.7 9.2 1 10.5 1 10.5
ns
t
PLZ
OE
Y C
L
= 50 pF
6.7 9.2 1 10.5 1 10.5
ns
t
sk(o)
C
L
= 50 pF 1** 1 ns
On products compliant to MIL-PRF-38535, this parameter is not production tested.
∗∗
On products compliant to MIL-PRF-38535, this parameter does not apply.