Datasheet
SCLS323M − MARCH 1996 − REVISED JUNE 2005
4
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
switching characteristics over recommended operating free-air temperature range,
V
CC
= 3.3 V ± 0.3 V (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
TO
LOAD
T
A
= 25°C
MIN
MAX
UNIT
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
LOAD
CAPACITANCE
MIN TYP MAX
MIN
MAX
UNIT
t
PLH
A or B
Y
C
L
= 15 pF
7 11 1 13
ns
t
PHL
A or B Y C
L
= 15 pF
7 11 1 13
ns
t
PLH
A or B
Y
C
L
= 50 pF
9.5 14.5 1 16.5
ns
t
PHL
A or B
Y
C
L
= 50 pF
9.5 14.5 1 16.5
ns
switching characteristics over recommended operating free-air temperature range,
V
CC
= 5 V ± 0.5 V (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
TO
LOAD
T
A
= 25°C
MIN
MAX
UNIT
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
LOAD
CAPACITANCE
MIN TYP MAX
MIN
MAX
UNIT
t
PLH
A or B
Y
C
L
= 15 pF
4.8 6.8 1 8
ns
t
PHL
A or B Y C
L
= 15 pF
4.8 6.8 1 8
ns
t
PLH
A or B
Y
C
L
= 50 pF
6.3 8.8 1 10
ns
t
PHL
A or B
Y
C
L
= 50 pF
6.3 8.8 1 10
ns
operating characteristics, V
CC
= 5 V, T
A
= 25°C
PARAMETER TEST CONDITIONS TYP UNIT
C