Datasheet
SN74AHC1G08
www.ti.com
SCLS314N –MARCH 1996–REVISED NOVEMBER 2012
ELECTRICAL CHARACTERISTICS
over operating free-air temperature range (unless otherwise noted)
T
A
= 25°C T
A
= –55°C to 125°C
PARAMETER TEST CONDITIONS V
CC
UNIT
MIN TYP MAX MIN MAX
2 V 1.9 2 1.9
I
OH
= –50 µA 3 V 2.9 3 2.9
V
OH
4.5 V 4.4 4.5 4.4 V
I
OH
= –4 mA 3 V 2.58 2.48
I
OH
= –8 mA 4.5 V 3.94 3.8
2 V 0.1 0.1
I
OL
= 50 µA 3 V 0.1 0.1
V
OL
4.5 V 0.1 0.1 V
I
OL
= 4 mA 3 V 0.36 0.44
I
OL
= 8 mA 4.5 V 0.36 0.44
I
I
V
I
= 5.5 V or GND 0 V to 5.5 V ±0.1 ±1 µA
I
CC
V
I
= V
CC
or GND, I
O
= 0 5.5 V 1 10 µA
C
i
V
I
= V
CC
or GND 5 V 4 10 10 pF
SWITCHING CHARACTERISTICS
over recommended operating free-air temperature range, V
CC
= 3.3 V ± 0.3 V (unless otherwise noted) (see Figure 1)
OUTPUT T
A
= 25°C T
A
= –40°C to 85°C T
A
= –55°C to 125°C
PARAMETE FROM TO
CAPACITAN UNIT
R (INPUT) (OUTPUT)
MIN TYP MAX MIN MAX MIN MAX
CE
t
PLH
6.2 8.8 1 10.5 1 11
A or B Y C
L
= 15 pF ns
t
PHL
6.2 8.8 1 10.5 1 11
t
PLH
8.7 12.3 1 14 1 14.5
A or B Y C
L
= 50 pF ns
t
PHL
8.7 12.3 1 14 1 14.5
SWITCHING CHARACTERISTICS
over recommended operating free-air temperature range, V
CC
= 5 V ± 0.5 V (unless otherwise noted) (see Figure 1)
OUTPUT T
A
= 25°C T
A
= –40°C to 85°C T
A
= –55°C to 125°C
PARAMETE FROM TO
CAPACITAN UNIT
R (INPUT) (OUTPUT)
MIN TYP MAX MIN MAX MIN MAX
CE
t
PLH
4.3 5.9 1 7 1 7.5
A or B Y C
L
= 15 pF ns
t
PHL
4.3 5.9 1 7 1 7.5
t
PLH
5.8 7.9 1 9 1 9.5
A or B Y C
L
= 50 pF ns
t
PHL
5.8 7.9 1 9 1 9.5
OPERATING CHARACTERISTICS
V
CC
= 5 V, T
A
= 25°C
PARAMETER TEST CONDITIONS TYP UNIT
C
pd
Power dissipation capacitance No load, f = 1 MHz 18 pF
Copyright © 1996–2012, Texas Instruments Incorporated Submit Documentation Feedback 3
Product Folder Links :SN74AHC1G08