Datasheet

SN74AHC1G00
www.ti.com
SCLS313N MARCH 1996REVISED MAY 2013
ELECTRICAL CHARACTERISTICS
over operating free-air temperature range (unless otherwise noted)
Recommended
T
A
= 25°C T
A
= –40°C to 85°C
PARAMETER TEST CONDITIONS V
CC
–40°C to 125°C UNIT
MIN TYP MAX MIN MAX MIN MAX
2 V 1.9 2 1.9 1.9
I
OH
= –50 µA 3 V 2.9 3 2.9 2.9
V
OH
4.5 V 4.4 4.5 4.4 4.4 V
I
OH
= –4 mA 3 V 2.58 2.48 2.48
I
OH
= –8 mA 4.5 V 3.94 3.8 3.8
2 V 0.1 0.1 0.1
I
OL
= 50 µA 3 V 0.1 0.1 0.1
V
OL
4.5 V 0.1 0.1 0.1 V
I
OL
= 4 mA 3 V 0.36 0.44 0.44
I
OL
= 8 mA 4.5 V 0.36 0.44 0.44
0 V to 5.5
I
I
V
I
= 5.5 V or GND ±0.1 ±1 ±1 µA
V
V
I
= V
CC
or
I
CC
I
O
= 0 5.5 V 1 10 10 µA
GND,
C
i
V
I
= V
CC
or GND 5 V 2 10 10 10 pF
SWITCHING CHARACTERISTICS
over recommended operating free-air temperature range, V
CC
= 3.3 V ± 0.3 V (unless otherwise noted) (see Figure 1)
Recommended
T
A
= –40°C to
T
A
= 25°C
FROM TO OUTPUT T
A
= –40°C to
85°C
PARAMETER UNIT
(INPUT) (OUTPUT) CAPACITANCE 125°C
TYP MAX MIN MAX MIN MAX
t
PLH
5.5 7.9 1 9.5 1 10.5
A or B Y C
L
= 15 pF ns
t
PHL
5.5 7.9 1 9.5 1 10.5
t
PLH
8 11.4 1 13 1 14
A or B Y C
L
= 50 pF ns
t
PHL
8 11.4 1 13 1 14
SWITCHING CHARACTERISTICS
over recommended operating free-air temperature range, V
CC
= 5 V ± 0.5 V (unless otherwise noted) (see Figure 1)
Recommended
T
A
= –40°C to
T
A
= 25°C
FROM TO OUTPUT T
A
= –40°C to
85°C
PARAMETER UNIT
(INPUT) (OUTPUT) CAPACITANCE 125°C
TYP MAX MIN MAX MIN MAX
t
PLH
3.7 5.5 1 6.5 1 7
A or B Y C
L
= 15 pF ns
t
PHL
3.7 5.5 1 6.5 1 7
t
PLH
5.2 7.5 1 6.5 1 9
A or B Y C
L
= 50 pF ns
t
PHL
5.2 7.5 1 6.5 1 9
OPERATING CHARACTERISTICS
V
CC
= 5 V, T
A
= 25°C
PARAMETER TEST CONDITIONS TYP UNIT
C
pd
Power dissipation capacitance No load, f = 1 MHz 9.5 pF
Copyright © 1996–2013, Texas Instruments Incorporated Submit Documentation Feedback 3
Product Folder Links :SN74AHC1G00