Absolute Maximum Ratings
(1)
SN74AHC123A-EP
DUAL RETRIGGERABLE MONOSTABLE MULTIVIBRATOR
SCLS703A JULY 2006 REVISED MARCH 2007
INPUT/OUTPUT TIMING DIAGRAM
over operating free-air temperature range (unless otherwise noted)
MIN MAX UNIT
V
CC
Supply voltage range
(2)
–0.5 7 V
V
I
Input voltage range
(3)
–0.5 7 V
V
O
Output voltage range in high or low state
(2)
–0.5 V
CC
+ 0.5 V
V
O
Output voltage range in power-off state
(2)
–0.5 7 V
I
IK
Input clamp current V
I
< 0 V –20 mA
I
OK
Output clamp current V
O
< 0 V or V
O
< V
CC
± 20 mA
I
O
Continuous output current V
O
= 0 V to V
CC
± 25 mA
Continuous current through V
CC
or GND ± 50 mA
θ
JA
Package thermal impedance
(4)
73 ° C/W
T
stg
Storage temperature range –65 150 ° C
(1) Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating
conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) Voltage values are with respect to the network ground terminal.
(3) The input and output voltage ratings may be exceeded if the input and output current ratings are observed.
(4) The package thermal impedance is calculated in accordance with JESD 51-7.