Datasheet
SN54ACT564, SN74ACT564
OCTAL D-TYPE EDGE-TRIGGERED FLIP-FLOPS
WITH 3-STATE OUTPUTS
SCAS549B – NOVEMBER 1995 – REVISED NOVEMBER 2002
4
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
timing requirements over recommended operating free-air temperature range, V
CC
= 5 V ± 0.5 V
(unless otherwise noted) (see Figure 1)
T
A
= 25°C SN54ACT564 SN74ACT564
UNIT
MIN MAX MIN MAX MIN MAX
UNIT
f
clock
Clock frequency 85 65 75 MHz
t
w
Pulse duration, CLK high or low 3 5 3.5 ns
t
su
Setup time, data before CLK↑ 2.5 3.5 3 ns
t
h
Hold time, data after CLK↑ 1 2.5 1 ns
switching characteristics over recommended operating free-air temperature range,
V
CC
= 5 V ± 0.5 V (unless otherwise noted) (see Figure 1)
PARAMETER
FROM TO
T
A
= 25°C SN54ACT564 SN74ACT564
UNIT
PARAMETER
(INPUT) (OUTPUT)
MIN TYP MAX MIN MAX MIN MAX
UNIT
f
max
85 90 65 75 MHz
t
PLH
CLK
Q
2 6.5 10.5 1 12.5 1.5 11.5
ns
t
PHL
CLK
Q
1.5 6 9.5 1 11.5 1.5 10.5
ns
t
PZH
OE
Q
1.5 5.5 9 1 10.5 1.5 9.5
ns
t
PZL
OE
Q
1.5 5.5 8.5 1 10.5 1 9.5
ns
t
PHZ
OE
Q
1.5 7 10.5 1 12.5 1.5 11.5
ns
t
PLZ
OE
Q
1.5 5 8 1 9.5 1 8.5
ns
operating characteristics, V
CC
= 5 V, T
A
= 25°C
PARAMETER TEST CONDITIONS TYP UNIT
C
pd
Power dissipation capacitance C
L
= 50 pF, f = 1 MHz 50 pF
PRODUCT PREVIEW information concerns products in the formative or
design phase of development. Characteristic data and other
specifications are design goals. Texas Instruments reserves the right to
change or discontinue these products without notice.