switching characteristics over recommended operating free-air temperature range,
V
CC
= 5 V " 5 V (unless otherwise noted) (see Figure 1)
PARAMETER
FROM TO
T
A
= 25°C SN54AC245 SN74AC245
UNIT
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
MIN TYP MAX MIN MAX MIN MAX
UNIT
t
PLH
AorB
BorA
1.5 3.5 6.5 1 8.5 1 7
ns
t
PHL
A or B B or A
1.5 3.5 6 1 7.5 1 7
ns
t
PZH
OE
AorB
1.5 5 8.5 1 10 1 9
ns
t
PZL
OE
A or B
1.5 5.5 9 1 10.5 1 9.5
ns
t
PHZ
OE
AorB
1.5 5.5 9 1 10.5 1 10
ns
t
PLZ
OE
A or B
1.5 5.5 9 1 10.5 1 10
ns
operating characteristics, V
CC
= 5 V, T
A
= 25°C
PARAMETER TEST CONDITIONS TYP UNIT
C
pd
Power dissipation capacitance per transceiver C
L
= 50 pF, f = 1 MHz 45 pF
PARAMETER MEASUREMENT INFORMATION
t
PHL
t
PLH
t
PLH
t
PHL
Input
Out-of-Phase
Output
50% 50%
50% V
CC
50% V
CC
50% V
CC
50% V
CC
V
CC
0 V
V
OL
V
OH
V
OH
V
OL
In-Phase
Output
VOLTAGE WAVEFORMS
From Output
Under Test
C
L
= 50 pF
(see Note A)
LOAD CIRCUIT
S1
2 × V
CC
500 Ω
500 Ω
Output
Control
(low-level
enabling)
Output
Waveform 1
S1 at 2 × V
CC
(see Note B)
Output
Waveform 2
S1 at Open
(see Note B)
V
OL
V
OH
t
PZL
t
PZH
t
PLZ
t
PHZ
50% V
CC
50% V
CC
V
CC
0 V
50% V
CC
V
OL
+ 0.3 V
50% V
CC
V
OH
− 0.3 V
0 V
V
CC
Open
VOLTAGE WAVEFORMS
t
PLH
/t
PHL
t
PLZ
/t
PZL
t
PHZ
/t
PZH
Open
2 × V
CC
Open
TEST S1
NOTES: A. C
L
includes probe and jig capacitance.
B. Waveform 1 is for an output with internal conditions such that the output is low except when disabled by the output control.
Waveform 2 is for an output with internal conditions such that the output is high except when disabled by the output control.
C. All input pulses are supplied by generators having the following characteristics: PRR 1 MHz, Z
O
= 50 Ω, t
r
v 2.5 ns, t
f
v 2.5 ns.
D. The outputs are measured one at a time with one input transition per measurement.
Figure 1. Load Circuit and Voltage Waveforms