Datasheet

SN54ABT8652, SN74ABT8652
SCAN TEST DEVICES
WITH OCTAL BUS TRANSCEIVERS AND REGISTERS
SCBS122F – AUGUST 1992 – REVISED DECEMBER 1996
19
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
Test-Logic-Reset
Run-Test/Idle
Select-DR-Scan
Select-IR-Scan
Capture-IR
Shift-IR
Exit1-IR
Update-IR
Select-DR-Scan
Capture-DR
Shift-DR
Exit1-DR
Update-DR
Select-DR-Scan
Select-IR-Scan
Test-Logic-Reset
TCK
TMS
TDI
TDO
TAP
Controller
State
3-State (TDO) or Don’t Care (TDI)
Figure 13. Timing Example
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage range, V
CC
–0.5 V to 7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input voltage range, V
I
: except I/O ports (see Note 1) –0.5 V to 7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
I/O ports (see Note 1) –0.5 V to 5.5 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Voltage range applied to any output in the high state or power-off state, V
O
–0.5 V to 5.5 V. . . . . . . . . . . . . .
Current into any output in the low state, I
O
: SN54ABT8652 96 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SN74ABT8652 128 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input clamp current, I
IK
(V
I
< 0) –18 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output clamp current, I
OK
(V
O
< 0) –50 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Maximum package power dissipation at T
A
= 55°C (in still air) (see Note 2): DL package 0.7 W. . . . . . . . . . .
DW package 1.7 W. . . . . . . . . .
Storage temperature range, T
stg
–65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. The input and output negative-voltage ratings may be exceeded if the input and output clamp-current ratings are observed.
2. The maximum package power dissipation is calculated using a junction temperature of 150°C and a board trace length of 750 mils.
For more information, refer to the
Package Thermal Considerations
application note in the
ABT Advanced BiCMOS Technology Data
Book
, literature number SCBD002.
recommended operating conditions (see Note 3)
SN54ABT8652 SN74ABT8652
UNIT
MIN MAX MIN MAX
UNIT
V
CC
Supply voltage 4.5 5.5 4.5 5.5 V
V
IH
High-level input voltage 2 2 V
V
IL
Low-level input voltage 0.8 0.8 V
V
I
Input voltage 0 V
CC
0 V
CC
V
I
OH
High-level output current –24 –32 mA
I
OL
Low-level output current 48 64 mA
t/v Input transition rise or fall rate 10 10 ns/V
T
A
Operating free-air temperature –55 125 –40 85 °C
NOTE 3: Unused pins (input or I/O) must be held high or low to prevent them from floating.