Datasheet

SN54ABT623A, SN74ABT623
OCTAL BUS TRANSCEIVERS
WITH 3-STATE OUTPUTS
SCBS114D – FEBRUARY 1991 – REVISED MAY 1997
4
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
T
A
= 25°C SN54ABT623A SN74ABT623
UNIT
PARAMETER
TEST
CONDITIONS
MIN TYP
MAX MIN MAX MIN MAX
UNIT
V
IK
V
CC
= 4.5 V, I
I
= –18 mA –1.2 –1.2 –1.2 V
V
CC
= 4.5 V, I
OH
= –3 mA 2.5 2.5 2.5
V
OH
V
CC
= 5 V, I
OH
= –3 mA 3 3 3
V
V
OH
V
CC
=45V
I
OH
= –24 mA 2 2
V
V
CC
=
4
.
5
V
I
OH
= –32 mA 2* 2
V
OL
V
CC
=45V
I
OL
= 48 mA 0.55 0.55
V
V
OL
V
CC
=
4
.
5
V
I
OL
= 64 mA 0.55* 0.55
V
V
hys
100 mV
I
I
Control inputs
V
CC
=55V
±1 ±1 ±1
µA
I
I
A or B ports
V
CC
=
5
.
5
V
,
I
=
CC
±100 ±100 ±100
µ
A
I
OZH
V
CC
= 5.5 V, V
O
= 2.7 V 50** 10 50 µA
I
OZL
V
CC
= 5.5 V, V
O
= 0.5 V –50** –10 –50 µA
I
off
V
CC
= 0, V
I
or V
O
4.5 V ±100 ±100 µA
I
CEX
V
CC
= 5.5 V,
V
O
= 5.5 V
Outputs high 50 50 50 µA
I
O
§
V
CC
= 5.5 V, V
O
= 2.5 V –50 –100 –180 –50 –180 –50 –180 mA
V
CC
=
5.5 V,
Outputs high 5 250 250 250 µA
I
CC
A or B ports
V
CC
=
5
.
5
V
,
I
O
= 0,
Outputs low 22 30 30 30 mA
V
I
= V
CC
or GND
Outputs disabled 1 250 250 250 µA
Data inp ts
V
CC
= 5.5 V, One
input at 3.4 V,
Outputs enabled 1.5 1.5 1.5
I
CC
D
ata
i
nputs
,
Other inputs at V
CC
or GND
Outputs disabled 0.05 0.05 0.05
mA
Control inputs
V
CC
= 5.5 V, One input at 3.4 V,
Other inputs at V
CC
or GND
1.5 1.5 1.5
C
i
Control inputs V
I
= 2.5 V or 0.5 V 4 pF
C
io
A or B ports V
O
= 2.5 V or 0.5 V 7 pF
* On products compliant to MIL-PRF-38535, this parameter does not apply.
** These limits apply only to the SN74ABT623.
All typical values are at V
CC
= 5 V.
The parameters I
OZH
and I
OZL
include the input leakage current.
§
Not more than one output should be tested at a time, and the duration of the test should not exceed one second.
This is the increase in supply current for each input that is at the specified TTL voltage level rather than V
CC