Datasheet

SN54ABT374, SN74ABT374A
OCTAL EDGE-TRIGGERED D-TYPE FLIP-FLOPS
WITH 3-STATE OUTPUTS
SCBS111G – FEBRUARY 1991 – REVISED JANUARY 1997
4
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
T
A
= 25°C SN54ABT374 SN74ABT374A
UNIT
PARAMETER
TEST
CONDITIONS
MIN TYP
MAX MIN MAX MIN MAX
UNIT
V
IK
V
CC
= 4.5 V, I
I
= –18 mA –1.2 –1.2 –1.2 V
V
CC
= 4.5 V, I
OH
= –3 mA
2.5 2.5 2.5
V
OH
V
CC
= 5 V, I
OH
= –3 mA
3 3 3
V
V
OH
V
CC
=45V
I
OH
= –24 mA
2 2
V
V
CC
=
4
.
5
V
I
OH
= –32 mA
2* 2
V
OL
V
CC
=45V
I
OL
= 48 mA
0.55 0.55
V
V
OL
V
CC
=
4
.
5
V
I
OL
= 64 mA
0.55* 0.55
V
V
hys
100 mV
I
I
V
CC
= 5.5 V, V
I
= V
CC
or GND ±1 ±1 ±1 µA
I
OZH
V
CC
= 5.5 V, V
O
= 2.7 V 10
10
10
µA
I
OZL
V
CC
= 5.5 V, V
O
= 0.5 V –10
–10
–10
µA
I
off
V
CC
= 0, V
I
or V
O
4.5 V ±100 ±100 µA
I
CEX
V
CC
= 5.5 V, V
O
= 5.5 V Outputs high 50 50 50 µA
I
O
§
V
CC
= 5.5 V, V
O
= 2.5 V –50 –100 –180 –50 –180 –50 –180 mA
V55VI0
Outputs high
250 250 250
µA
I
CC
V
CC
= 5.5 V, I
O
= 0,
V
I
=V
CC
or GND
Outputs low
30 30 30
mA
V
I
=
V
CC
or
GND
Outputs disabled
250 250 250
µA
I
CC
V
CC
= 5.5 V, One input at 3.4 V,
Other inputs at V
CC
or GND
1.5 1.5 1.5 mA
C
i
V
I
= 2.5 V or 0.5 V 3.5 pF
C
o
V
O
= 2.5 V or 0.5 V 6.5 pF
* On products compliant to MIL-PRF-38535, this parameter does not apply.
All typical values are at V
CC
= 5 V.
This data sheet limit may vary among suppliers.
§
Not more than one output should be tested at a time, and the duration of the test should not exceed one second.
This is the increase in supply current for each input that is at the specified TTL voltage level rather than V
CC
or GND.
timing requirements over recommended ranges of supply voltage and operating free-air
temperature (unless otherwise noted) (see Figure 1)
SN54ABT374
V
CC
= 5 V,
T
A
= 25°C
MIN MAX
UNIT
MIN MAX
f
clock
Clock frequency 0 150 0 150 MHz
t
w
Pulse duration CLK high or low 3.3 3.3 ns
t
su
Setu
p
time before CLK
Data high 2 2.5
ns
t
su
Setup
time
before
CLK
Data low 2 2.5
ns
t
h
Hold time after CLK Data high or low 2 2.5 ns