Datasheet

SN74ABT18502
SCAN TEST DEVICE
WITH 18-BIT REGISTERED BUS TRANSCEIVER
SCBS753 FEBRUARY 2002
24
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
recommended operating conditions (see Note 3)
MIN MAX UNIT
V
CC
Supply voltage 4.5 5.5 V
V
IH
High-level input voltage 2 V
V
IL
Low-level input voltage 0.8 V
V
I
Input voltage 0 V
CC
V
I
OH
High-level output current 32 mA
I
OL
Low-level output current 64 mA
t/v Input transition rise or fall rate 10 ns/V
T
A
Operating free-air temperature 40 85 °C
NOTE 3: All unused inputs of the device must be held at V
CC
or GND to ensure proper device operation. Refer to the TI application report,
Implications of Slow or Floating CMOS Inputs, literature number SCBA004.
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
T
A
= 25°C
MIN
MAX
UNIT
PARAMETER
TEST
CONDITIONS
MIN TYP
MAX
MIN
MAX
UNIT
V
IK
V
CC
= 4.5 V, I
I
= 18 mA 1.2 1.2 V
V
CC
= 4.5 V, I
OH
= 3 mA 2.5 2.5
V
OH
V
CC
= 5 V, I
OH
= 3 mA 3 3
V
V
OH
V
CC
= 4.5 V, I
OH
= 24 mA 2 2
V
V
CC
= 4.5 V, I
OH
= 32 mA 2
V
OL
V
CC
=45V
I
OL
= 48 mA 0.55 0.55
V
V
OL
V
CC
=
4
.
5
V
I
OL
= 64 mA 0.55
V
I
I
V
CC
=55V
V
I
=V
CC
or GND
CLK,LE,OE,TCK ±1 ±1
µA
I
I
V
CC
=
5
.
5
V
,
V
I
=
V
CC
or
GND
A or B ports ±100 ±100
µ
A
I
IH
V
CC
= 5.5 V, V
I
= V
CC
TDI, TMS 10 10 µA
I
IL
V
CC
= 5.5 V, V
I
= GND TDI, TMS 150 150 µA
I
OZH
V
CC
= 5.5 V, V
O
= 2.7 V 50 50 µA
I
OZL
V
CC
= 5.5 V, V
O
= 0.5 V 50 50 µA
I
OZPU
V
CC
= 0 to 2 V, V
O
= 2.7 V or 0.5 V,
OE = 0.8 V
±50 ±50 µA
I
OZPD
V
CC
= 2 V to 0, V
O
= 2.7 V or 0.5 V,
OE = 0.8 V
±50 ±50 µA
I
off
V
CC
= 0, V
I
or V
O
4.5 V ±100 ±450 µA
I
CEX
V
CC
= 5.5 V, V
O
= 5.5 V Outputs high 50 50 µA
I
O
§
V
CC
= 5.5 V, V
O
= 2.5 V 50 110 200 50 200 mA
V
CC
=
5.5 V,
Outputs high 3.5 5.5 5.5
I
CC
V
CC
=
5
.
5
V
,
I
O
= 0,
A or B ports
Outputs low 33 38 38
mA
V
I
= V
CC
or GND
Outputs disabled 2.9 5 5
I
CC
V
CC
= 5.5 V, One input at 3.4 V, Other inputs at V
CC
or GND 50 50 µA
C
i
V
I
= 2.5 V or 0.5 V Control inputs 3 pF
C
io
V
O
= 2.5 V or 0.5 V A or B ports 10 pF
C
o
V
O
= 2.5 V or 0.5 V TDO 8 pF
All typical values are at V
CC
= 5 V.
The parameters I
OZH
and I
OZL
include the input leakage current.
§
Not more than one output should be tested at a time, and the duration of the test should not exceed one second.
This is the increase in supply current for each input that is at the specified TTL voltage level rather than V
CC
or GND.