Datasheet
SN54ABT16821, SN74ABT16821
20-BIT BUS-INTERFACE FLIP-FLOPS
WITH 3-STATE OUTPUTS
SCBS216B – JUNE 1992 – REVISED JANUARY 1997
5
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
timing requirements over recommended ranges of supply voltage and operating free-air
temperature (unless otherwise noted) (see Figure 1)
V
CC
= 5 V,
T
A
= 25°C
SN54ABT16821 SN74ABT16821
UNIT
MIN MAX MIN MAX MIN MAX
f
clock
Clock frequency 0 150 0 150 0 150 MHz
t
w
Pulse duration, CLK high or low 3.3 3.3 3.3 ns
t
su
Setup time, data before CLK↑ 1.8 1.8 1.8 ns
t
h
Hold time, data after CLK↑ 1.3 1.3 1.3 ns
switching characteristics over recommended ranges of supply voltage and operating free-air
temperature, C
L
= 50 pF (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
V
CC
= 5 V,
T
A
= 25°C
SN54ABT16821 SN74ABT16821
UNIT
(INPUT)
(OUTPUT)
MIN TYP MAX MIN MAX MIN MAX
f
max
150 150 150 MHz
t
PLH
CLK
Q
1.3 3.7 5.1 1.3 6.7 1.3 6.1
ns
t
PHL
CLK
Q
1.6 3.9 5.1 1.6 5.8 1.6 5.4
ns
t
PZH
OE
Q
1.1 3.2 4.7 1.1 5.8 1.1 5.7
ns
t
PZL
OE
Q
1.6 3.8 5 1.6 5.7 1.6 5.6
ns
t
PHZ
OE
Q
2 4.5 5.7 2 6.6 2 6.5
ns
t
PLZ
OE
Q
1.8 4.1 5.8 1.8 8.4 1.8 7.1
ns
PRODUCT PREVIEW information concerns products in the formative or
design phase of development. Characteristic data and other
specifications are design goals. Texas Instruments reserves the right to
change or discontinue these products without notice.