Datasheet

SN54ABT16646, SN74ABT16646
16-BIT BUS TRANSCEIVERS AND REGISTERS
WITH 3-STATE OUTPUTS
SCBS212D – JUNE 1992 – REVISED JULY 1999
7
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
T
A
= 25°C SN54ABT16646 SN74ABT16646
UNIT
PARAMETER
TEST
CONDITIONS
MIN TYP
MAX MIN MAX MIN MAX
UNIT
V
IK
V
CC
= 4.5 V, I
I
= –18 mA –1.2 –1.2 –1.2 V
V
CC
= 4.5 V, I
OH
= –3 mA 2.5 2.5 2.5
V
OH
V
CC
= 5 V, I
OH
= –3 mA 3 3 3
V
V
OH
V
CC
=45V
I
OH
= –24 mA 2 2
V
V
CC
=
4
.
5
V
I
OH
= –32 mA 2* 2
V
OL
V
CC
=45V
I
OL
= 48 mA 0.55 0.55
V
V
OL
V
CC
=
4
.
5
V
I
OL
= 64 mA 0.55* 0.55
V
V
hys
100 mV
I
I
Control
inputs
V
CC
= 5.5 V, V
I
= V
CC
or GND
±1 ±1 ±1
µ
A
I
A or B ports
CC
,
ICC
±20 ±20 ±20
µ
I
OZH
V
CC
= 5.5 V, V
O
= 2.7 V 10 10 10 µA
I
OZL
V
CC
= 5.5 V, V
O
= 0.5 V –10 –10 –10 µA
I
off
V
CC
= 0, V
I
or V
O
4.5 V ±100 ±100 µA
I
CEX
V
CC
= 5.5 V,
V
O
= 5.5 V
Outputs high 50 50 50 µA
I
O
§
V
CC
= 5.5 V, V
O
= 2.5 V –50 –100 –180 –50 –180 –50 –180 mA
V
CC
=
5.5 V,
Outputs high 2 2 2
I
CC
A or B ports
V
CC
=
5
.
5
V
,
I
O
= 0,
Outputs low 32 32 32
mA
V
I
= V
CC
or GND
Outputs disabled 2 2 2
p
V
CC
= 5.5 V,
One input at 3.4 V,
Outputs enabled 50 50 50
I
CC
u
,
Other inputs at
V
CC
or GND
Outputs disabled 50 50 50
µA
Control
inputs
V
CC
= 5.5 V, One input at 3.4 V,
Other inputs at V
CC
or GND
50 50 50
C
i
Control
inputs
V
I
= 2.5 V or 0.5 V 4 pF
C
io
A or B ports V
O
= 2.5 V or 0.5 V 8 pF
* On products compliant to MIL-PRF-38535, this parameter does not apply.
All typical values are at V
CC
= 5 V.
The parameters I
OZH
and I
OZL
include the input leakage current.
§
Not more than one output should be tested at a time, and the duration of the test should not exceed one second.
This is the increase in supply current for each input that is at the specified TTL voltage level rather than V
CC
or GND.