Datasheet
www.ti.com
APPLICATION INFORMATION
COMPARISON OF MLVD TO TIA/EIA-485
Receiver Input Threshold (Failsafe)
-100
-50
0
50
100
150
200
Type 1
Transition Regions
Type 2
Low
High
Low
High
- Differential Input Voltage - mV
V
ID
SN65MLVD200A , SN65MLVD202A
SN65MLVD204A , SN65MLVD205A
SLLS573 – DECEMBER 2003
The MLVD standard defines a type 1 and type 2 receiver. Type 1 receivers include no provisions for failsafe and
have their differential input voltage thresholds near zero volts. Type 2 receivers have their differential input
voltage thresholds offset from zero volts to detect the absence of a voltage difference. The impact to receiver
output by the offset input can be seen in Table 3 and Figure 27 .
Table 3. Receiver Input Voltage Threshold Requirements
RECEIVER TYPE OUTPUT LOW OUTPUT HIGH
Type 1 –2.4 V ≤ V
ID
≤ -0.05 V 0.05 V ≤ V
ID
≤ 2.4 V
Type 2 –2.4 V ≤ V
ID
≤ 0.05 V 0.15 V ≤ V
ID
≤ 2.4 V
Figure 27. Expanded Graph of Receiver Differential Input Voltage Showing Transition Region
18
Submit Documentation Feedback