Datasheet

www.ti.com
4
3
1
2
DE
D
RE
R
6
7
A
B
LOGIC DIAGRAM (POSITIVE LOGIC)
5
4
2
3
DE
D
RE
R
12
11
A
B
10
9
Y
Z
SN65MLVD202A, SN65MLVD205A
SN65MLVD200A, SN65MLVD204A
PACKAGE DISSIPATION RATINGS
ABSOLUTE MAXIMUM RATINGS
SN65MLVD200A , SN65MLVD202A
SN65MLVD204A , SN65MLVD205A
SLLS573 DECEMBER 2003
These devices have limited built-in ESD protection. The leads should be shorted together or the device placed in conductive foam
during storage or handling to prevent electrostatic damage to the MOS gates.
ORDERING INFORMATION
PART NUMBER
(1)
FOOTPRINT RECEIVER TYPE PACKAGE MARKING
SN65MLVD200AD SN75176 Type 1 MF200A
SM65MLVD202AD SN75ALS180 Type 1 MLVD202A
SN65MLVD204AD SN75176 Type 2 MF204A
SM65MLVD205AD SN75ALS180 Type 2 MLVD205A
(1) Available tape and reeled. To order a tape and reeled part, add the suffix R to the part number (e.g., SN65MLVD200ADR).
T
A
25 ° C DERATING FACTOR T
A
= 85 ° C
PACKAGE
POWER RATING ABOVE T
A
= 25°C POWER RATING
D(8) 532 mW 4.6 mW/ ° C 254 mW
D(14) 940 mW 8.2 mW/ ° C 450 mw
over operating free-air temperature range unless otherwise noted
(1)
SN65MLVD200A,
202A, 204A, and 205A
Supply voltage range
(2)
, V
CC
–0.5 V to 4 V
D, DE, RE –0.5 V to 4 V
Input voltage range A, B (200A, 204A) –1.8 V to 4 V
A, B (202A, 205A) –4 V to 6 V
R –0.3 V to 4 V
Output voltage range
Y, Z, A, or B –1.8 V to 4 V
A, B, Y, and Z ± 8 kV
Human Body Model
(3)
Electrostatic discharge All pins ± 4 kV
Charged-Device Model
(4)
All pins ± 1500 V
Continuous power dissipation See Dissipation Rating Table
Storage temperature range –65 ° C to 150 ° C
(1) Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under recommended operating
conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltage values, except differential I/O bus voltages, are with respect to network ground terminal.
(3) Tested in accordance with JEDEC Standard 22, Test Method A114-A.
(4) Tested in accordance with JEDEC Standard 22, Test Method C101.
2