Datasheet
www.ti.com
SN65MLVD047
SLLS606A – MARCH 2004 – REVISED JULY 2005
APPLICATION INFORMATION (continued)
Note: Channel 1: V
CC
, Channel 2: Differential Bus
Voltage
The output state of the part during this voltage range is independent of the EN and EN pins.
In order to insure that data is not corrupted during a live insertion event or the power cycling of an individual
node on a multipoint bus it is important to isolate the outputs of the device from the bus until the V
CC
has
reached at least 2.0 VDC. At this voltage level the device output state accurately reflects the logic conditions as
defined in the Device Function Table.
13