Datasheet
www.ti.com
SWITCHING CHARACTERISTICS
PARAMETER MEASUREMENT INFORMATION
V
ID
B or R
IN–
V
IB
or V
RIN–
V
IA
or V
RIN+
V
IC
(V
IA
+ V
IB
)/2 or
(V
RIN+
+ V
RIN–)/2
V
OY
or V
ROUT
I
OY
or I
ROUT
Y or R
OUT
A or R
IN+
I
IA
or I
RIN+
I
IB
or I
RIN–
SN65LVDS348 , SN65LVDT348
SN65LVDS352 , SN65LVDT352
SLLS523E – FEBRUARY 2002 – REVISED MAY 2004
over recommended operating conditions (unless otherwise noted)
PARAMETER TEST CONDITIONS MIN TYP
(1)
MAX UNIT
t
PLH
Propagation delay time, low-to-high-level output 2.5 4 6 ns
t
PHL
Propagation delay time, high-to-low-level output 2.5 4 6 ns
t
d1
Delay time, failsafe disable time 12 ns
t
d2
Delay time, failsafe enable time 0.3 1.5 µs
t
sk(p)
Pulse skew (|t
pHL1
- t
pLH1
|) C
L
= 10 pF, See Figure 3 200 ps
t
sk(o)
Output skew
(2)
150 ps
t
sk(pp)
Part-to-part skew
(3)
1 ns
t
r
Output signal rise time 1.2 ns
t
f
Output signal fall time 1 ns
t
r
Output signal rise time 650 ps
C
L
= 1 pF, See Figure 3
t
f
Output signal fall time 400 ps
t
PHZ
Propagation delay time, high-level-to-high-impedance output 5 9 ns
t
PLZ
Propagation delay time, low-level-to-high-impedance output 5 9 ns
See Figure 4 and Figure 5
t
PZH
Propagation delay time, high-impedance-to-high-level output 8 12 ns
t
PZL
Propagation delay time, high-impedance-to-low-level output 8 12 ns
(1) All typical values are at 25°C and with a 3.3-V supply.
(2) t
sk(o)
is the magnitude of the time difference between the t
PHL
or t
PLH
of all receivers of a single device with all of their inputs connected
together.
(3) t
sk(pp)
is the magnitude of the difference in propagation delay times between any specified terminals of two devices when both devices
operate with the same supply voltages, at the same temperature, and have identical packages and test circuits.
Figure 1. Voltage and Current Definitions
7