Datasheet
C
L
= 10 pF Max
(2 Places)
49.9 Ω ± 1% (2 Places)
V
OC
V
OD
YP
YM
V
OD(H)
V
OC(SS)
V
OC(SS)
V
OD(L)
100%
80%
20%
0%
0 V
V
OC(PP)
t
r
t
f
0 V
(a) SCHEMATIC
(b) WAVEFORMS
NOTE A: The lumped instrumentation capacitance for any single-ended voltage measurement is less than or equal to 10 pF. When making
measurements at YP or YM, the complementary output is similarly loaded.
SN65LVDS84AQ-Q1
www.ti.com
........................................................................................................................................................ SLLS766A – AUGUST 2006 – REVISED APRIL 2008
PARAMETER MEASUREMENT INFORMATION (continued)
Figure 3. Test Load and Voltage Definitions for LVDS Outputs
Copyright © 2006 – 2008, Texas Instruments Incorporated Submit Documentation Feedback 7
Product Folder Link(s): SN65LVDS84AQ-Q1