Datasheet
A
>75kW
BUSHold
Y
SN65LVDS315
SLLS881F –DECEMBER 2007–REVISED SEPTEMBER 2012
www.ti.com
APPLICATION INFORMATION
RECEIVER TERMINATION REQUIREMENT
The SN65LVDS315 outputs two differential lanes that must be specially terminated near the CSI-1 receiver
device. As shown in Figure 26, place two resistors and one capacitor in each lane (within ±20% to the values
shown). There are two possible implementations, based on whether the termination inside the receiver device
can be disabled. If it can be disabled, place the components as close to the receiver as possible. This RC filter is
a requirement that adds stability to the common mode voltage.
Figure 26. CSI-1 Receiver Device Termination
PREVENTING CONTROL INPUTS FROM INCREASED LEAKAGE CURRENTS
To ensure the lowest possible leakage current during
standby or power down, all inputs must be held static.
Any kind of input switching will cause increased
leakage current. Hold inputs TXEN and MODE either
at V
IH
or V
IL
. The LVDS315 incorporates a bus-hold
feature on the D[0:7] inputs, DCLK, VS, and HS. This
feature ensures that the input-stage leakage current
is minimized during times when the camera output is
in a high impedance state. Inputs with the bus-hold
feature can be left open without the need of an
external pullup or pulldown. This feature minimizes
the power consumption of standby and power down
modes in particular.
24 Submit Documentation Feedback Copyright © 2007–2012, Texas Instruments Incorporated
Product Folder Links :SN65LVDS315