Datasheet

www.ti.com
ABSOLUTE MAXIMUM RATINGS
DISSIPATION RATINGS
RECOMMENDED OPERATING CONDITIONS
SN65LVDS20
SN65LVP20
SLLS620A JUNE 2004 REVISED SEPTEMBER 2005
These devices have limited built-in ESD protection. The leads should be shorted together or the device
placed in conductive foam during storage or handling to prevent electrostatic damage to the MOS gates.
AVAILABLE OPTIONS
(1)
INPUT OUTPUT PART NUMBER PART MARKING
Differential LVDS SN65LVDS20 E8
Differential LVPECL SN65LVP20 E7
(1) For the most current package and ordering information, see the Package Option Addendum at the end of this document, or see the TI
website at www.ti.com.
over operating free-air temperature range (unless otherwise noted)
(1)
UNIT
V
CC
Supply voltage
(2)
-0.5 V to 4 V
V
I
Input voltage -0.5 V to V
CC
+ 0.5 V
V
O
Output voltage -0.5 V to V
CC
+ 0.5 V
I
O
V
BB
output current ±0.5 mA
HBM electrostatic discharge
(3)
±3 kV
CDM electrostatic discharge
(4)
±1500 V
Continuous power dissipation See Power Dissipation Ratings Table
(1) Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings
only and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating
conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltage values, except differential voltages, are with respect to network ground (see Figure 2 ).
(3) Tested in accordance with JEDEC Standard 22, Test Method A114-A-7
(4) Tested in accordance with JEDEC Standard 22, Test Method C101
T
A
< 25°C OPERATING FACTOR T
A
= 85°C
PACKAGE
POWER RATING ABOVE T
A
= 25°C POWER RATING
DRF 403 mW 4.0 mW/°C 161 mW
MIN NOM MAX UNIT
V
CC
Supply Voltage 2.375 2.5 or 3.3 3.6 V
V
IC
Common-mode input voltage (V
IA
+ V
IB
)/2 1.2 V
CC
- (V
ID
/2) V
|V
ID
| Differential input voltage magnitude, |V
IA
- V
IB
| 0.08 1 V
V
IH
High-level input voltage, EN 2 V
CC
V
V
IL
Low-level input voltage, EN 0 0.8 V
I
O
Output current to V
BB
-400
(1)
400 µA
R
L
Differential load resistance 90 132
T
A
Operating free-air temperature -40 85 °C
(1) The algebraic convention, where the least positive (more negative) value is designated minimum, is used in this data sheet.
2