Datasheet
SN65LVDS180-Q1
SN65LVDS050-Q1
SN65LVDS051-Q1
SGLS204C –SEPTEMBER 2003–REVISED MARCH 2013
www.ti.com
PARAMETER MEASUREMENT INFORMATION (continued)
A. All input pulses are supplied by a generator having the following characteristics: t
r
or t
f
≤ 1 ns, pulse repetition rate
(PRR) = 50 Mpps, pulse width = 10 ± 0.2 ns. C
L
includes instrumentation and fixture capacitance within 0,06 mm of
the D.U.T. The measurement of V
OC(PP)
is made on test equipment with a –3-dB bandwidth of at least 300 MHz.
Figure 3. Test Circuit and Definitions for the Driver Common-Mode Output Voltage
A. All input pulses are supplied by a generator having the following characteristics: t
r
or t
f
≤ 1 ns, pulse repetition rate
(PRR) = 0.5 Mpps, pulse width = 500 ± 10 ns. C
L
includes instrumentation and fixture capacitance within 0,06 mm of
the D.U.T.
Figure 4. Enable and Disable Time Circuit and Definitions
8 Submit Documentation Feedback Copyright © 2003–2013, Texas Instruments Incorporated
Product Folder Links: SN65LVDS180-Q1 SN65LVDS050-Q1 SN65LVDS051-Q1