Datasheet

Evaluation Module U2
1-4
1.4 Evaluation Module U2
Figure 1−2. Power Connections for Evaluation Module U2
Pattern
Generator
Oscilloscope
EVM
Power Supply 1
+
Power Supply 2
+
VCC
EVM
GND
DUT
GND
1.2V
3.3V
Matched
Cables
SMA to SMA
Matched
Cables
SMA to SMA
P3
J8
J7
J6
J5
P4 P2
R6
100
50 50
J9
R7
Uninstalled
Warning
Power jacks P2, P3, and P4 are not insulated on the backside of the
EVM. Place the EVM on a nonconductive surface.
1.5 Applying an Input to EVM U2
Inputs should be applied to SMA connectors J5 and J6, while keeping R6
installed. The EVM comes with a 100- termination resistor (R6) installed
across the differential inputs for terminating the transmission line.
When using a general-purpose signal generator with 50- output impedance,
make sure that the signal levels are between 0 V to V
CC
with respect to P4.
V
ID
cannot exceed 2 V. A signal generator such as the Advantest D3186 can
simulate LVPECL, LVDS, or CML inputs.
LVPECL levels can be obtained with 100- differential input termination by
setting the input generator to a common-mode of 0.7 V.