Datasheet
www.ti.com
ABSOLUTE MAXIMUM RATINGS
DISSIPATION RATING TABLE
RECOMMENDED OPERATING CONDITIONS
SN65LVDS109
SN65LVDS117
SLLS369F – AUGUST 1999 – REVISED FEBRUARY 2005
over operating free-air temperature range (unless otherwise noted)
(1)
UNIT
Supply voltage range, V
CC
(2)
–0.5 V to 4 V
Enable inputs –0.5 V to 6 V
Input voltage range
A, B, Y or Z –0.5 V to 4 V
Electrostatic discharge A, B, Y, Z, and GND
(3)
Class 3, A:12 kV, B: 500 V
Continuous power dissipation See Dissipation Rating Table
Storage temperature range –65 ° C to 150 ° C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds 260 ° C
(1) Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under recommended operating
conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltage values, except differential I/O bus voltages, are with respect to network ground terminal.
(3) Tested in accordance with MIL-STD-883C Method 3015.7.
T
A
≤ 25 ° C DERATING FACTOR
(1)
T
A
= 85 ° C
PACKAGE
POWER RATING ABOVE T
A
= 25 ° C POWER RATING
DBT 1277 mW 10.2 mW/ ° C 644 mW
DGG 2094 mW 16.7 mW/ ° C 1089 mW
(1) This is the inverse of the junction-to-ambient thermal resistance when board-mounted (low-k) with no
air flow.
MIN NOM MAX UNIT
V
CC
Supply voltage 3 3.3 3.6 V
V
IH
High-level input voltage 2 V
V
IL
Low-level input voltage 0.8 V
V
I
or V
IC
Voltage at any bus terminal (separately or common-mode) 0 V
CC
– 0.8 V
T
A
Operating free-air temperature –40 85 ° C
4