Datasheet
www.ti.com
ABSOLUTE MAXIMUM RATINGS
DISSIPATION RATING TABLE
RECOMMENDED OPERATING CONDITIONS
SN65LVDS104
SN65LVDS105
SLLS396F – SEPTEMBER 1999 – REVISED JANUARY 2005
over operating free-air temperature range (unless otherwise noted)
(1)
UNIT
Supply voltage range, V
CC
(2)
–0.5 to 4 V
Enables, A ('LVDS105) –0.5 to 6 V
Voltage range
A, B, Y or Z –0.5 to 4 V
Electrostatic discharge
(3)
A, B, Y, Z, and GND Class 3, A:16 kV, B: 400 V
Continuous power dissipation See Dissipation Rating Table
Storage temperature range –65 ° C to 150 ° C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds 260 ° C
(1) Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under recommended operating
conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltage values, except differential I/O bus voltages, are with respect to network ground terminal.
(3) Tested in accordance with MIL-STD-883C Method 3015.7
T
A
≤ 25 ° C OPERATING FACTOR
(1)
T
A
= 85 ° C
PACKAGE
POWER RATING ABOVE T
A
= 25 ° C POWER RATING
D 950 mW 7.6 mW/ ° C 494 mW
PW 774 mW 6.2 mW/ ° C 402 mW
(1) This is the inverse of the junction-to-ambient thermal resistance when board-mounted (low-k) and
with no air flow.
MIN NOM MAX UNIT
V
CC
Supply voltage 3 3.3 3.6 V
V
IH
High-level input voltage 2 V
V
IL
Low-level input voltage 0.8 V
V
I
or V
IC
Voltage at any bus terminal (separately or common-mode) 0 V
CC
–0.8
T
A
Operating free-air temperature –40 85 ° C
3