FAIL SAFE
Rt = 100 Ω (Typ)
300 kΩ 300 kΩ
V
CC
V
IT
≈ 2.3 V
A
B
Y
SN65LVDS104
SN65LVDS105
SLLS396F – SEPTEMBER 1999 – REVISED JANUARY 2005
APPLICATION INFORMATION (continued)
A common problem with differential signaling applications is how the system responds when no differential
voltage is present on the signal pair. The LVDS receiver is like most differential line receivers, in that its output
logic state can be indeterminate when the differential input voltage is between –100 mV and 100 mV and within
its recommended input common-mode voltage range. Hovever, TI LVDS receivers handles the open-input circuit
situation differently.
Open-circuit means that there is little or no input current to the receiver from the data line itself. This could be
when the driver is in a high-impedance state or the cable is disconnected. When this occurs, the LVDS receiver
pulls each line of the signal pair to near V
CC
through 300-k Ω resistors as shown in Figure 33 . The fail-safe
feature uses an AND gate with input voltage thresholds at about 2.3 V to detect this condition and force the
output to a high-level regardless of the differential input voltage.
Figure 33. Open-Circuit Fail Safe of the LVDS Receiver
It is only under these conditions that the output of the receiver will be valid with less than a 100 mV differential
input voltage magnitude. The presence of the termination resistor, Rt, does not affect the fail-safe function as
long as it is connected as shown in Figure 33 . Other termination circuits may allow a dc current to ground that
could defeat the pullup currents from the receiver and the fail-safe feature.
19