Datasheet

www.ti.com
V
OC
Z
Y
Input
C
L
= 10 pF
(2 Places)
3 V
0 V
V
OC(PP)
V
OC(SS)
V
OC
49.9 , ±1% (2 Places)
Driver Enable
SN65LVDS1050
SLLS343B APRIL 1999 REVISED APRIL 2003
All input pulses are supplied by a generator having the following characteristics: t
r
or t
f
1 ns, pulse repetition rate (PRR) = 50 Mpps, pulse
width = 10 ± 0.2 ns . C
L
includes instrumentation and fixture capacitance within 0,06 mm of the D.U.T. The measurement of V
OC(PP)
is made
on test equipment with a -3 dB bandwidth of at least 300 MHz.
Figure 3. Test Circuit and Definitions for the Driver Common-Mode Output Voltage
All input pulses are supplied by a generator having the following characteristics: t
r
or t
f
1 ns, pulse repetition rate (PRR) = 0.5 Mpps, pulse
width = 500 ± 10 ns . C
L
includes instrumentation and fixture capacitance within 0,06 mm of the D.U.T.
Figure 4. Driver Enable and Disable Time Circuit and Definitions
7