Datasheet

www.ti.com
2.4
V
ID
2
V
ID
2
SN65LVDS049
SLLS575AUGUST 2003
ABSOLUTE MAXIMUM RATINGS
over operating free-air temperature range (unless otherwise noted)
(1)
UNIT
Supply voltage range
(2)
, V
CC
-0.3 V to 4 V
D
IN
, R
OUT
, EN, or EN -0.3 V to (V
CC
+ 0.3 V)
Voltage range R
IN+
or R
IN-
-0.3 V to 4 V
D
OUT+
or D
OUT-
-0.3 V to 3.9 V
R
IN+
, R
IN-
, D
OUT+
, and D
OUT-
±10 kV
Human Body Model
(3)
ESD All pins ±2K V
Charged-Device Model
(4)
All pins ±500 V
LVDS output short circuit duration (DOUT+, DOUT-) Continuous
Continuous power dissipation See Dissipation Rating Table
Storage temperature range -65°C to 150°C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds 260°C
(1)
Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings
only and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating
conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability
(2)
All voltage values, except differential I/O bus voltages, are with respect to network ground terminal.
(3)
Tested in accordance with JEDEC Standard 22, Test Method A114-A.
(4)
Tested in accordance with JEDEC Standard 22, Test Method C101.
RECOMMENDED OPERATING CONDITIONS
MIN NOM MAX UNIT
Supply voltage, V
CC
3 3.3 3.6 V
Receiver input voltage GND V
Common-mode input voltage, V
IC
V
V
CC
- 0.8 V
Operating free-air temperature, T
A
-40 85 °C
3