Datasheet
V
ID
2
2.4 *
ǒ
V
ID
2
Ǔ
SN65LV1023A
SN65LV1224B
www.ti.com
SLLS621E –SEPTEMBER 2004–REVISED DECEMBER 2009
ABSOLUTE MAXIMUM RATINGS
over operating free-air temperature range (unless otherwise noted)
(1)
UNIT
V
CC
to GND −0.3 V to 4 V
LVTTL input voltage −0.3 V to (V
CC
+ 0.3 V)
LVTTL output voltage −0.3 V to (V
CC
+ 0.3 V)
LVDS receiver input voltage −0.3 V to 3.9 V
LVDS driver output voltage −0.3 V to 3.9 V
LVDS output short circuit duration 10 ms
HBM up to 6 kV
Electrostatic discharge:
MM up to 200 V
Junction temperature 150°C
Storage temperature −65°C to 150°C
DB package maximum package T
A
= 25°C
1.27 W
power dissipation
RHB package maximum package T
A
= 25°C
2.85 W
power dissipation
DB package derating 10.3 mW/°C above 25°C
RHB package derating 23.6 mW/°C above 25°C
(1) Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under recommended operating
conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
RECOMMENDED OPERATING CONDITIONS
over operating free-air temperature range (unless otherwise noted)
MIN NOM MAX UNIT
V
CC
(1)
Supply voltage 3 3.3 3.6 V
Receiver input voltage range 0 2.4 V
V
CM
Receiver input common mode range V
Supply noise voltage 100 mV
PP
T
A
Operating free-air temperature –40 25 °C
(1) By design, DVCC and AVCC are separated internally and does not matter what the difference is for |DVCC−AVCC|, as long as both are
within 3 V to 3.6 V.
Copyright © 2004–2009, Texas Instruments Incorporated Submit Documentation Feedback 7
Product Folder Link(s): SN65LV1023A SN65LV1224B