Datasheet

SN65LBC179A
SN75LBC179A
www.ti.com
SLLS377D MAY 2000 REVISED SEPTEMBER 2011
ABSOLUTE MAXIMUM RATINGS
(1)
over operating free-air temperature range (unless otherwise noted)
UNIT
V
CC
Supply voltage range
(2)
0.3 V to 6 V
A, B, Y, or Z
(2)
10 V to 15 V
Voltage range
D or R
(2)
0.3 V to V
CC
+ 0.5 V
I
O
Receiver output current ±20 mA
Bus terminals and GND, Class 3, A
(3)
12 kV
Bus terminals and GND, Class 3, B
(3)
400 V
Electrostatic discharge
All terminals, Class 3, A 3 kV
All terminals, Class 3, B 400 V
Continuous total power dissipation
(4)
Internally limited
Total power dissipation See Dissipation Rating Table
(1) Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under recommended operating
conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltage values, except differential I/O bus voltages, are with respect to GND.
(3) Tested in accordance with MIL-STD-883C, Method 3015.7
(4) The maximum operating junction temperature is internally limited. Uses the dissipation rating table to operate below this temperature.
DISSIPATION RATINGS
PACKAGE T
A
25°C DERATING FACTOR
(1)
T
A
= 70°C T
A
= 85°C
POWER RATING ABOVE T
A
= 25°C POWER RATING POWER RATING
D 725 mW 5.8 mW/°C 464 mW 377 mW
P 1100 mW 8.08 mW/°C 640 mW 520 mW
(1) This is the inverse of the junction-to-ambient thermal resistance when board-mounted and with no air flow.
RECOMMENDED OPERATING CONDITIONS
MIN NOM MAX UNIT
V
CC
Supply voltage 4.75 5 5.25 V
V
IH
High-level input voltage D 2 V
CC
V
V
IL
Low-level input voltage D 0 0.8 V
V
ID
Differential input voltage
(1)
12
(2)
12 V
V
O
V
I
Voltage at any bus terminal (separately or common-mode) A, B, Y, or Z 7 12 V
V
IC
Y or Z 60
I
OH
High-level output current mA
R 8
Y or Z 60
I
OL
Low-level output current mA
R 8
SN65LBC179A 40 85
T
A
Operating free-air temperature °C
SN75LBC179A 0 70
(1) Differential input/output bus voltage is measured at the noninverting terminal with respect to the inverting terminal.
(2) The algebraic convention, in which the least positive (most negative) limit is designated as minimum, is used in this data sheet.
Copyright © 20002011, Texas Instruments Incorporated Submit Documentation Feedback 3
Product Folder Link(s): SN65LBC179A SN75LBC179A