Datasheet

 
    
SLLS455C − NOVEMBER 2000 − REVISED MARCH 2009
3
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
absolute maximum ratings
over operating free-air temperature range (unless otherwise noted)
Supply voltage range, V
CC
(see Note 1) −0.3 V to 6 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Voltage range at any bus input (steady state), A and B −10 V to 15 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Voltage range at any bus input (transient pulse through 100 , see Figure 5) −30 V to 30 V. . . . . . . . . . . . . .
Voltage input range at 1,2EN and 3,4EN, V
I
−0.5 V to V
CC
+ 0.5 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Receiver output current, I
O
±10 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electrostatic discharge:
Human body model (see Note 2): A and B to GND 6 kV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
All pins 5 kV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Charged-device model (see Note 3): All pins 2 kV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous power dissipation See Power Dissipation Rating Table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. All voltage values, except differential I/O bus voltages, are with respect to GND, and are steady-state (unless otherwise specified).
2. Tested in accordance with JEDEC Standard 22, Test Method A114-A.
3. Tested in accordance with JEDEC Standard 22, Test Method C101.
DISSIPATION RATING TABLE
PACKAGE
T
A
25°C
POWER RATING
DERATING FACTOR
ABOVE T
A
= 25°C
T
A
= 70°C
POWER RATING
T
A
= 85°C
POWER RATING
D 1080 mW 8.7 mW/°C 690 mW 560 mW
N 1150 mW 9.2 mW/°C 736 mW 598 mW
This is the inverse of the junction-to-ambient thermal resistance when board-mounted and with no air
flow.
recommended operating conditions
MIN NOM MAX UNIT
Supply voltage, V
CC
4.75 5 5.25 V
Voltage at any bus terminal A, B −7 12 V
High-level input voltage, V
IH
EN
2 V
CC
V
Low-level input voltage, V
IL
EN
0 0.8
V
Output current Y −8 8 mA
SN75LBC175A 0 70
°C
Operating free-air temperature, T
A
SN65LBC175A −40 85
°C