Datasheet

 
    
SLLS163E − JULY 1993 − REVISED APRIL 2006
6
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
PARAMETER MEASUREMENT INFORMATION
R
L
= 110
VOLTAGE WAVEFORMSTEST CIRCUIT
Output
Input
t
PZH
1.5 V
2.3 V
0.5 V
t
PHZ
1.5 V
V
OH
V
off
0 V
0 V
3 V
Output
Generator
(see Note A)
0 V or 3 V
50
S1
C
L
= 50 pF
(see Note B)
Input
NOTES: A. The input pulse is supplied by a generator having the following characteristics: PRR 1 MHz, duty cycle = 50%, t
r
5 ns,
t
f
5 ns, Z
O
= 50 .
B. C
L
includes probe and stray capacitance.
Figure 4. t
PZH
and t
PHZ
Test Circuit and Voltage Waveforms
VOLTAGE WAVEFORMSTEST CIRCUIT
Output
R
L
= 110
C
L
= 50 pF
(see Note B)
50
5 V
5 V
V
OL
0.5 V
t
PZL
3 V
t
PLZ
1.5 V
2.3 V
1.5 V
Output
Input
0 V
3 V
(see Note C)
0 V or 3 V
S1
Input
Generator
(see Note A)
NOTES: A. The input pulse is supplied by a generator having the following characteristics: PRR 1 MHz, duty cycle = 50%, t
r
5 ns,
t
f
5 ns, Z
O
= 50 .
B. C
L
includes probe and stray capacitance
C. To test the active-low enable G
, ground G and apply an inverted waveform to G..
Figure 5. t
PZL
and t
PLZ
Test Circuit and Waveforms