Datasheet
www.ti.com
RECOMMENDED OPERATING CONDITIONS
(1)
SUPPLY CURRENT
ELECTROSTATIC DISCHARGE PROTECTION
SN65HVD485E
SLLS612C – JUNE 2004 – REVISED MARCH 2007
MIN TYP MAX UNIT
V
CC
Supply voltage 4.5 5.5 V
V
I
Input voltage at any bus terminal (separately or common mode) –7 12 V
V
IH
High-level input voltage (D, DE, or RE inputs) 2 V
CC
V
V
IL
Low-level input voltage (D, DE, or RE inputs) 0 0.8 V
V
ID
Differential input voltage –12 12 V
Driver –60 60
I
O
Output current mA
Receiver –8 8
R
L
Differential load resistance 54 60 Ω
1/t
UI
Signaling rate 0 10 Mbps
T
A
Operating free-air temperature –40 85 ° C
T
J
Junction temperature
(2)
–40 130 ° C
(1) The algebraic convention, in which the least positive (most negative) limit is designated as minimum, is used in this data sheet.
(2) See thermal characteristics table for information on maintenance of this specification for the DGK package.
over recommended operating conditions (unless otherwise noted)
PARAMETER TEST CONDITIONS MIN TYP
(1)
MAX UNIT
Driver and receiver enabled D at V
CC
or open or 0V, DE at V
CC
, RE at 0V, No load 2 mA
I
CC
Driver and receiver
D at V
CC
or open, DE at 0V, RE at V
CC
1 mA
disabled
(1) All typical values are at 25 ° C and with a 5-V supply.
PARAMETER TEST CONDITIONS MIN TYP
(1)
MAX UNIT
Human body model Bus terminals and GND ± 15 kV
Human body model
(2)
All pins ± 4 kV
Charged-device-model
(3)
All pins ± 1 kV
(1) All typical values at 25 ° C
(2) Tested in accordance with JEDEC Standard 22, Test Method A114-A.
(3) Tested in accordance with JEDEC Standard 22, Test Method C101.
3
Submit Documentation Feedback