ABSOLUTE MAXIMUM RATINGS
RECOMMENDED OPERATING CONDITIONS
SN65HVD379
SLLS667B – FEBRUARY 2006 – REVISED JUNE 2008 ....................................................................................................................................................
www.ti.com
This integrated circuit can be damaged by ESD. Texas Instruments recommends that all integrated circuits be handled with
appropriate precautions. Failure to observe proper handling and installation procedures can cause damage.
ESD damage can range from subtle performance degradation to complete device failure. Precision integrated circuits may be more
susceptible to damage because very small parametric changes could cause the device not to meet its published specifications.
ORDERING INFORMATION
SIGNALING RATE UNIT LOADS PART NUMBER
(1)
SOIC MARKING
25 Mbps 1/2 SN65HVD379
(1) These are The D package is available taped and reeled. Add an R suffix to the part number (ie. SN65HVD379DR).
over operating free-air temperature range unless otherwise noted
(1) (2)
UNIT
V
CC
Supply voltage range – 0.3 V to 6 V
V
A
, V
B
, V
Y
, V
Z
Voltage range at any bus terminal (A, B, Y, Z) – 9 V to 14 V
V
TRANS
Voltage input, transient pulse through 100 Ω . See Figure 8 (A, B, Y, Z)
(3)
– 50 to 50 V
V
I
Input voltage range (D, DE, RE) -0.5 V to 7 V
P
CONT
Continuous total power dissipation Internally limited
(4)
I
O
Output current (receiver output only, R) 11 mA
(1) Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under recommended operating
conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltage values, except differential I/O bus voltages, are with respect to network ground terminal.
(3) This tests survivability only and the output state of the receiver is not specified.
(4) The Thermal shutdown protection circuit internally limits the continuous total power dissipation. Thermal shutdown typically occurs when
the junction temperature reaches 165C.
over operating free-air temperature range unless otherwise noted
PARAMETER MIN NOM MAX UNIT
V
CC
Supply voltage 3 3.6
V
V
I
or V
IC
Voltage at any bus terminal (separately or common mode) – 7
(1)
12
1/t
UI
Signaling rate SN65HVD379 25 Mbps
R
L
Differential load resistance 54 60 Ω
V
IH
High-level input voltage D 2 V
CC
V
IL
Low-level input voltage D 0 0.8 V
V
ID
Differential input voltage – 12 12
Driver – 60
I
OH
High-level output current mA
Receiver – 8
Driver 60
I
OL
Low-level output current mA
Receiver 8
T
A
Ambient still-air temperature – 40 85 C
(1) The algebraic convention, in which the least positive (most negative) limit is designated as minimum is used in this data sheet.
2 Submit Documentation Feedback Copyright © 2006 – 2008, Texas Instruments Incorporated
Product Folder Link(s): SN65HVD379