SN65HVD257 EVM Setup and Operation for Redundant (Parallel Networks)
3.2 Using CAN Bus Load and Termination Configuration
Each bus of the EVM is populated with two 120Ω power resistors selectable via jumpers between CANH
and CANL. By using one of the resistors, the EVM may be used as a terminated end of a bus. For
electrical measurements to represent the total loading of the bus, use both 120Ω resistors in parallel to
give the standard 60Ω load for parametric measurement. The EVM also has footprints for customer
installation of split termination if the application requires it. The table below summarizes how to use these
termination options. If split termination is used, care must be taken to match the resistors. The common-
mode filter frequency may be calculated by: f
c
= 1 / (2 π R C). Normally, the split capacitance is in the
range of 4.7nF to 100nF. Keep in mind that this is the common-mode filter frequency, not a differential
filter that will impact the differential CAN signal directly.
Table 3. CAN Bus Termination Configuration
Split Termination CM Stabilizing
120Ω Resistors
Footprints Capacitor
"Termination Configuration Bus 1"
JMP4 JMP6 R5 R13 C3
Standard Termination (120Ω) shorted open NA NA NA
60Ω load - Electrical Parameterics shorted shorted NA NA NA
Split Termination (Common Mode
open open 60Ω 60Ω populated
Stabilization)
Split Termination CM Stabilizing
"Termination Configuration Bus 2" 120Ω Resistors
Footprints Capacitor
JMP9 JMP11 R29 R37 C23
Standard Termination (120Ω) shorted open NA NA NA
60Ω load - Electrical Parameterics shorted shorted NA NA NA
Split Termination (Common Mode
open open 60Ω 60Ω populated
Stabilization)