Datasheet

SN65HVD233-HT
www.ti.com
SLLS933F NOVEMBER 2008REVISED AUGUST 2012
DRIVER SWITCHING CHARACTERISTICS
over operating free-air temperature range (unless otherwise noted)
T
A
= –55°C to 125°C T
A
= 175°C
(1)
T
A
= 210°C
(2)
PARAMETER TEST CONDITIONS UNIT
MIN TYP MAX MIN TYP MAX MIN TYP MAX
R
S
= 0 V, See Figure 5 35 85 50 50
Propagation delay
R
S
with 10 k to ground,
time, 70 125 75 75
t
PLH
See Figure 5 ns
low-to-high-level
R
S
with 100 k to ground,
output
500 870 500 500
See Figure 5
R
S
= 0 V,
70 120 70 70
See Figure 5
Propagation delay
time, R
S
with 10 k to ground,
t
PHL
130 180 130 130 ns
high-to-low-level See Figure 5
output
R
S
with 100 k to ground,
870 1200 870 870
See Figure 5
R
S
= 0 V,
35 9 9
See Figure 5
Pulse skew R
S
with 10 k to ground,
t
sk(p)
60 35 35 ns
(|t
PHL
– t
PLH
|) See Figure 5
R
S
with 100 k to ground,
370 475 475
See Figure 5
Differential output
t
r
20 70 20 75 20 75
signal rise time
R
S
= 0 V, See Figure 5 ns
Differential output
t
f
18 70 20 75 20 75
signal fall time
Differential output
t
r
30 135 30 140 30 140
signal rise time
R
S
with 10 k to ground,
ns
See Figure 5
Differential output
t
f
30 135 30 140 30 140
signal fall time
Differential output
t
r
250 1400 250 1400 250 1400
signal rise time
R
S
with 100 k to ground,
ns
See Figure 5
Differential output
t
f
350 1400 350 1400 350 1400
signal fall time
Enable time from
t
en(s)
standby to See Figure 9 0.6 1.5 0.6 1.5 0.6 1.5 μs
dominant
(1) Minimum and maximum parameters are characterized for operation at T
A
= 210°C but not production tested at T
A
= 175°C or 210°C.
(2) Minimum and maximum parameters are characterized for operation at T
A
= 210°C but may not be production tested at that temperature.
Production test limits with statistical guardbands are used to ensure high temperature performance.
RECEIVER ELECTRICAL CHARACTERISTICS
over operating free-air temperature range (unless otherwise noted)
T
A
= –55°C to 125°C T
A
= 175°C
(1)
T
A
= 210°C
(2)
PARAMETER TEST CONDITIONS UNIT
MIN TYP MAX MIN TYP MAX MIN TYP MAX
Positive-going input
V
IT+
620 900 600 900 600 900 mV
threshold voltage
Negative-going
V
IT–
input threshold LBK = 0 V, See Table 2 500 715 500 725 500 725 mV
voltage
Hysteresis voltage
V
hys
100 140 140 mV
(V
IT+
– V
IT–
)
High-level output
V
OH
I
O
= –4 mA, See Figure 7 2.4 2.4 2.4 V
voltage
(1) Minimum and maximum parameters are characterized for operation at T
A
= 210°C and are not chacterized or production tested at
T
A
= 175°C.
(2) Minimum and maximum parameters are characterized for operation at T
A
= 210°C but may not be production tested at that temperature.
Production test limits with statistical guardbands are used to ensure high temperature performance.
Copyright © 2008–2012, Texas Instruments Incorporated Submit Documentation Feedback 9