Datasheet
100 Ω
CANH
CANL
Rs, LBK, at 0 V or V
CC
Pulse Generator
15 µs Duration
1% Duty Cycle
t
r
, t
f
≤ 100 ns
R
D at 0 V or V
CC
I
O
R
CANH
CANL
V
I
2.2V 2.2V
2.9V
1.5V
V
OH
V
OL
90%
10%
t
r
t
f
50%
V
I
V
O
t
PLH
t
PHL
(seeNote A)
1.5V
C
L
=15pF ±20%
(seeNoteB)
V
O
10%
90%
50%
V
O
I
O
R
V
ID
CANH
CANL
V
I(CANL)
V
I(CANH)
V
I(CANH
+ V
I(CANL)
2
V
IC
=
SN65HVD233-HT
SLLS933F –NOVEMBER 2008–REVISED AUGUST 2012
www.ti.com
PARAMETER MEASUREMENT INFORMATION (continued)
Figure 6. Receiver Voltage and Current Definitions
A. The input pulse is supplied by a generator having the following characteristics: Pulse repetition rate (PRR) ≤ 125 kHz,
50% duty cycle, t
r
≤ 6 ns, t
f
≤ 6 ns, Z
O
= 50 Ω.
B. C
L
includes fixture and instrumentation capacitance.
Figure 7. Receiver Test Circuit and Voltage Waveforms
Table 2. Differential Input Voltage Threshold Test
INPUT OUTPUT MEASURED
V
CANH
V
CANL
R |V
ID
|
–6.1 V –7 V L 900 mV
12 V 11.1 V L 900 mV
V
OL
–1 V –7 V L 6 V
12 V 6 V L 6 V
–6.5 V –7 V H 500 mV
12 V 11.5 V H 500 mV
–7 V –1 V H V
OH
6 V
6 V 12 V H 6 V
Open Open H X
NOTE: This test is conducted to test survivability only. Data stability at the R output is not specified.
Figure 8. Test Circuit, Transient Over Voltage Test
14 Submit Documentation Feedback Copyright © 2008–2012, Texas Instruments Incorporated
Product Folder Links: SN65HVD233-HT