Datasheet
SN65HVD230Q-Q1
SN65HVD231Q-Q1
SN65HVD232Q-Q1
SGLS398A − APRIL 2002 − REVISED APRIL 2008
11
www.ti.com
PARAMETER MEASUREMENT INFORMATION
50 Ω
Signal
Generator
(see Note A)
C
L
= 15 pF
(see Note B)
1.5 V
90%
Output
1.3 V
10%
t
f
V
OL
V
OH
t
r
Input
1.5 V
2.9 V
t
P(HL)
2.2 V
t
P(LH)
Output
NOTES: A. The input pulse is supplied by a generator having the following characteristics: PRR ≤ 500 kHz, 50% duty cycle, t
r
≤ 6 ns, t
f
≤ 6 ns,
Zo = 50 Ω.
B. C
L
includes probe and jig capacitance.
Figure 6. Receiver Test Circuit and Voltage Waveforms
100 Ω
Pulse Generator,
15 µs Duration,
1% Duty Cycle
Figure 7. Overvoltage Protection