APPLICATION INFORMATION
THEORY OF OPERATION
The SN65HVD21A integrates a differential receiver and differential driver with additional features for improved
performance in electrically-noisy, long-cable, or other fault-intolerant applications.
The receiver hysteresis (typically 130 mV) is much larger than found in typical RS-485 transceivers. This helps
reject spurious noise signals which would otherwise cause false changes in the receiver output state.
Slew rate limiting on the driver outputs reduces the high-frequency content of signal edges. This decreases
reflections from bus discontinuities, and allows longer stub lengths between nodes and the main bus line.
Designers should consider the maximum signaling rate and cable length required for a specific application, and
choose the transceiver best matching those requirements.
When DE is low, the differential driver is disabled, and the A and B outputs are in high-impedance states. When
DE is high, the differential driver is enabled, and drives the A and B outputs according to the state of the D
inputs.
When RE is high, the differential receiver output buffer is disabled, and the R output is in a high-impedance state.
When RE is low, the differential receiver is enabled, and the R output reflects the state of the differential bus
inputs on the A and B pins.
If both the driver and receiver are disabled, (DE low and RE high) then all nonessential circuitry, including
auxiliary functions such as failsafe and receiver equalization is placed in a low-power standby state. This reduces
power consumption to less than 5µW. When either enable input is asserted, the circuitry again becomes active.
In addition to the primary differential receiver, these devices incorporate a set of comparators and logic to
implement an active receiver failsafe feature. These components determine whether the differential bus signal is
valid. Whenever the differential signal is close to zero volts (neither high nor low), a timer initiates, If the
differential input remains within the transition range for more than 250 microseconds, the timer expires and set
the receiver output to the high state. If a valid bus input (high or low) is received at any time, the receiver output
reflects the valid bus state, and the timer is reset.
Figure 23. Function Block Diagram
Copyright © 2010, Texas Instruments Incorporated Submit Documentation Feedback 15