Datasheet

SurfaceNode
JC
Calculated/Measured
Junction
JB
Calculated/Measured
PCBoard
CA
Calculated
AmbientNode
q
q
q
SN65HVD1176
SN75HVD1176
SLLS563F JULY 2003REVISED JUNE 2013
www.ti.com
APPLICATION INFORMATION
Thermal Characteristics of IC Packages
θ
JA
(Junction-to-Ambient Thermal Resistance) is defined as the difference in junction temperature to ambient
temperature divided by the operating power.
θ
JA
is not a constant and is a strong function of:
PCB design (50% variation)
altitude (20% variation)
device power (5% variation)
θ
JA
can be used to compare the thermal performance of packages if the specific test conditions are defined and
used. Standardized testing includes specification of PCB construction, test chamber volume, sensor locations,
and the thermal characteristics of holding fixtures. θ
JA
is often misused when it is used to calculate junction
temperatures for other installations.
TI uses two test PCBs as defined by JEDEC specifications. The low-k board gives average in-use condition
thermal performance, and it consists of a single copper trace layer 25 mm long and 2-oz thick. The high-k board
gives best case in-use condition, and it consists of two 1-oz buried power planes with a single copper trace layer
25 mm long and 2-oz thick. A 4% to 50% difference in θ
JA
can be measured between these two test cards
θ
JC
(Junction-to-Case Thermal Resistance) is defined as difference in junction temperature to case divided by
the operating power. It is measured by putting the mounted package up against a copper block cold plate to
force heat to flow from die, through the mold compound into the copper block.
θ
JC
is a useful thermal characteristic when a heatsink is applied to package. It is not a useful characteristic to
predict junction temperature because it provides pessimistic numbers if the case temperature is measured in a
nonstandard system and junction temperatures are backed out. It can be used with θ
JB
in 1-dimensional thermal
simulation of a package system.
θ
JB
(Junction-to-Board Thermal Resistance) is defined as the difference in the junction temperature and the
PCB temperature at the center of the package (closest to the die) when the PCB is clamped in a cold-plate
structure. θ
JB
is only defined for the high-k test card. θ
JB
provides an overall thermal resistance between the die
and the PCB. It includes a bit of the PCB thermal resistance (especially for BGA’s with thermal balls) and can be
used for simple 1-dimensional network analysis of package system (see Figure 21).
Figure 21. Thermal Resistance
14 Submit Documentation Feedback Copyright © 2003–2013, Texas Instruments Incorporated
Product Folder Links: SN65HVD1176 SN75HVD1176