Datasheet

www.ti.com
Input
Generator 50
Generator: PRR = 100 kHz, 50% Duty Cycle, t
r
< 6 ns, t
f
< 6 ns, Z
o
= 50
V
O
RE
R
A
B
3 V
1.5 V
t
PZH(2)
1.5 V
3 V
0 V
V
OH
GND
V
I
V
O
0 V or 1.5 V
1.5 V or 0 V C
L
= 15 pF ±20%
C
L
Includes Fixture
and Instrumentation
Capacitance
V
I
1 k ± 1%
A
B
S1
A at 1.5 V
B at 0 V
S1 to B
t
PZL(2)
1.5 V
3 V
V
OL
V
O
A at 0 V
B at 1.5 V
S1 to A
Pulse Generator,
15 µs Duration,
1% Duty Cycle
t
r
, t
f
100 ns
100
± 1%
_
+
A
B
R
D
DE
RE
0 V or 3 V
NOTE
:
This test is conducted to test survivability only. Data stability at the R output is not specified.
3 V or 0 V
SN65HVD10-EP , , SN65HVD11-EP
SN65HVD12-EP
SGLS278E DECEMBER 2004 REVISED SEPTEMBER 2007
PARAMETER MEASUREMENT INFORMATION (continued)
Figure 11. Receiver Enable Time From Standby (Driver Disabled)
Figure 12. Test Circuit, Transient Over Voltage Test
12 Submit Documentation Feedback Copyright © 2004 2007, Texas Instruments Incorporated
Product Folder Link(s): SN65HVD10-EP SN65HVD11-EP SN65HVD12-EP