Datasheet

SN65HVD1040-Q1
www.ti.com
SLLS753D FEBRUARY 2007 REVISED AUGUST 2011
ABSOLUTE MAXIMUM RATINGS
(1) (2)
over operating free-air temperature range (unless otherwise noted)
VALUE
V
CC
Supply voltage range 0.3 V to 6 V
Voltage range at bus terminals (CANH, CANL, SPLIT) 27 V to 40 V
I
O
Receiver output current 20 mA
V
I
Voltage input range, ac transient pulse
(3)
(CANH, CANL) 200 V to 200 V
V
I
Voltage input range (TXD, STB) 0.3 V to 6 V
T
J
Junction temperature range 40°C to 170°C
T
A
Operating free-air temperature range 40°C to 125°C
(1) Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating
conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltage values, except differential I/O bus voltages, are with respect to network ground terminal.
(3) Tested in accordance with ISO 7637-1, test pulses 1, 2, 3a, 3b, 5, 6, and 7. ISO 7637-1 transient tests are ac only; if dc may be coupled
in with ac transients, externally protect the bus pins within the absolute maximum voltage range at any bus terminal (27 V to 40 V). If
common-mode chokes are used in the system and the bus lines may be shorted to dc, ensure that the choke type and value in
combination with the node termination and shorting voltage either does not create inductive flyback outside of voltage maximum
specification or use an external transient-suppression circuit to protect the transceiver from the inductive transients.
ELECTROSTATIC DISCHARGE PROTECTION
over operating free-air temperature range (unless otherwise noted)
PARAMETER TEST CONDITIONS VALUE
Bus terminals (CANH, CANL, SPLIT) and GND ±8 kV
Human-Body Model
(2)
All pins ±4 kV
Electrostatic discharge
(1)
Charged-Device Model
(3)
All pins ±1 kV
Machine Model ±200 V
(1) All typical values at 25°C.
(2) Tested in accordance JEDEC Standard 22, Test Method A114-A.
(3) Tested in accordance JEDEC Standard 22, Test Method C101.
RECOMMENDED OPERATING CONDITIONS
MIN MAX UNIT
V
CC
Supply voltage 4.75 5.25 V
V
I
or V
IC
Voltage at any bus terminal (separately or common mode) 12 12 V
V
IH
High-level input voltage TXD, STB 2 5.25 V
V
IL
Low-level input voltage TXD, STB 0 0.8 V
V
ID
Differential input voltage 6 6 V
Driver 70
I
OH
High-level output current mA
Receiver 2
Driver 70
I
OL
Low-level output current mA
Receiver 2
T
J
Junction temperature See Thermal Characteristics table 150 °C
SUPPLY CURRENT
over recommended operating conditions including operating free-air temperature range (unless otherwise noted)
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
Standby mode STB at V
CC
, V
I
= V
CC
6 12 μA
I
CC
5-V supply current Dominant V
I
= 0 V, 60- load, STB at 0 V 50 70
mA
Recessive V
I
= V
CC
, No load, STB at 0 V 6 10
Copyright © 20072011, Texas Instruments Incorporated 3